Evaluation of low-temperature fracture toughness and minimum allowable temperature of SA-372 Gr. J Class 70 steel for hydrogen vessels

SA-372 Gr. J Class 70 steel has been widely deployed in more than one thousand 90 MPa-class hydrogen pressure vessels across South Korea, where its structural integrity has been validated under conventional service conditions ranging from –40 °C to + 85 °C. However, as hydrogen infrastructures expand toward liquefied and solid hydrogen systems, SA-372 is increasingly being considered as a candidate material for buffer storage tanks that may experience transitional sub-ambient temperatures (down to –40 °C). In this transitional role, existing exemption rules and accumulated service data are insufficient to ensure safe operation. To address this gap, this study experimentally evaluated the low-temperature fracture toughness of SA-372 Gr. J Class 70 using Charpy V-notch impact tests between + 23 °C and –80 °C. The absorbed energy data were analyzed through hyperbolic tangent fitting to construct a ductile-to-brittle transition curve, from which key parameters such as transition temperature and lower shelf energy were derived. These results were incorporated into a Level 3 Option C procedure of API 579–1 / ASME FFS-1, and combined with the Master Curve methodology to estimate temperature-dependent fracture toughness K mat (T). Fracture Assessment Diagram (FAD) analyses were then performed to determine the Minimum Allowable Temperature (MAT) under both inert and hydrogen-charged conditions, with hydrogen embrittlement incorporated via a conservative threshold toughness of K IH = 40 MPa√m. The results showed that while SA-372 maintains sufficient toughness below –60 °C in air, the MAT for 90 MPa service pressure was constrained to –24.1 °C when considering hydrogen exposure. This indicates that conventional exemption criteria (27 J at –40 °C) may be non-conservative for buffer tank applications bridging current gaseous systems and emerging cryogenic hydrogen infrastructures. By quantifying this critical temperature shift, the present work provides a mechanics-based safety framework for SA-372 vessels, supporting risk-informed inspection and design strategies in next-generation hydrogen energy systems.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2026-02-05
DOI
https://doi.org/10.1016/j.nxmate.2026.101663
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of low-temperature fracture toughness and minimum allowable temperature of SA-372 Gr. J Class 70 steel for hydrogen vessels

M. A. Lee, Hwa-young Lee, Jeong Hwan Kim, Giyoek Ha
Next Materials
Hydrogen embrittlement and corrosion behaviors in metals
article

Evaluation of low-temperature fracture toughness and minimum allowable temperature of SA-372 Gr. J Class 70 steel for hydrogen vessels

M. A. Lee, Hwa-young Lee, Jeong Hwan Kim, Giyoek Ha
article en

Abstract

SA-372 Gr. J Class 70 steel has been widely deployed in more than one thousand 90 MPa-class hydrogen pressure vessels across South Korea, where its structural integrity has been validated under conventional service conditions ranging from –40 °C to + 85 °C. However, as hydrogen infrastructures expand toward liquefied and solid hydrogen systems, SA-372 is increasingly being considered as a candidate material for buffer storage tanks that may experience transitional sub-ambient temperatures (down to –40 °C). In this transitional role, existing exemption rules and accumulated service data are insufficient to ensure safe operation. To address this gap, this study experimentally evaluated the low-temperature fracture toughness of SA-372 Gr. J Class 70 using Charpy V-notch impact tests between + 23 °C and –80 °C. The absorbed energy data were analyzed through hyperbolic tangent fitting to construct a ductile-to-brittle transition curve, from which key parameters such as transition temperature and lower shelf energy were derived. These results were incorporated into a Level 3 Option C procedure of API 579–1 / ASME FFS-1, and combined with the Master Curve methodology to estimate temperature-dependent fracture toughness K mat (T). Fracture Assessment Diagram (FAD) analyses were then performed to determine the Minimum Allowable Temperature (MAT) under both inert and hydrogen-charged conditions, with hydrogen embrittlement incorporated via a conservative threshold toughness of K IH = 40 MPa√m. The results showed that while SA-372 maintains sufficient toughness below –60 °C in air, the MAT for 90 MPa service pressure was constrained to –24.1 °C when considering hydrogen exposure. This indicates that conventional exemption criteria (27 J at –40 °C) may be non-conservative for buffer tank applications bridging current gaseous systems and emerging cryogenic hydrogen infrastructures. By quantifying this critical temperature shift, the present work provides a mechanics-based safety framework for SA-372 vessels, supporting risk-informed inspection and design strategies in next-generation hydrogen energy systems.

Next MaterialsVol. 11
Seoul National University of Science and Technology (KR), Kangwon National University (KR), Korea Gas Corporation (South Korea) (KR)
Industry, innovation and infrastructure
Openalex Percentile: Top 69%
Hydrogen embrittlement and corrosion behaviors in metals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.