Low-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries

We present a novel, low-cost optical sensor for accurate real-time monitoring of the state of charge (SoC) and total vanadium concentration in vanadium flow batteries. Using only six discrete wavelengths, the sensor achieves precision comparable to full-spectrum methods while significantly reducing equipment costs and complexity. A general deconvolution method is used to measure the SoC and the total vanadium concentration in both the negolyte and posolyte, with calibration covering concentrations from 1.21 to 1.82 mol/L. We achieve root mean square error (RMSE) values of 1.2% and 3.2% for the SoC, and 54 mmol/L and 97 mmol/L for the total vanadium concentration in the negolyte and posolyte, respectively, demonstrating excellent agreement with reference ultraviolet visible (UV-vis) data. In addition, a wavelength optimization study is proposed to determine the optimal number and placement of spectral channels, providing a basis for the design of tailored optical sensors for vanadium electrolytes.

Authors

Publication Details

Journal
Advanced Sensor and Energy Materials
Published
2026-02-06
DOI
https://doi.org/10.1016/j.asems.2026.100183
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries

Ange Anicet Maurice, Marcos Vera, Pablo A. Prieto-Díaz
Advanced Sensor and Energy Materials
Advanced battery technologies research
article

Low-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries

Ange Anicet Maurice, Marcos Vera, Pablo A. Prieto-Díaz
article en

Abstract

We present a novel, low-cost optical sensor for accurate real-time monitoring of the state of charge (SoC) and total vanadium concentration in vanadium flow batteries. Using only six discrete wavelengths, the sensor achieves precision comparable to full-spectrum methods while significantly reducing equipment costs and complexity. A general deconvolution method is used to measure the SoC and the total vanadium concentration in both the negolyte and posolyte, with calibration covering concentrations from 1.21 to 1.82 mol/L. We achieve root mean square error (RMSE) values of 1.2% and 3.2% for the SoC, and 54 mmol/L and 97 mmol/L for the total vanadium concentration in the negolyte and posolyte, respectively, demonstrating excellent agreement with reference ultraviolet visible (UV-vis) data. In addition, a wavelength optimization study is proposed to determine the optimal number and placement of spectral channels, providing a basis for the design of tailored optical sensors for vanadium electrolytes.

Advanced Sensor and Energy MaterialsVol. 5(1)
Affordable and clean energy
Openalex Percentile: Top 65%
Advanced battery technologies research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.