Shape-Sensing Robotic-Assisted Bronchoscopy vs. Electromagnetic Robotic-Assisted Bronchoscopy—A Comparative Cohort Study

<b>Introduction</b>: Lung cancer is a leading cause of cancer-related deaths globally, with approximately 1.5 million new peripheral pulmonary lesions (PPLs) detected annually in the United States. Robotic-assisted bronchoscopy (RAB) has emerged as a promising technology, with two platforms initially approved, the Monarch platform (Auris Health Inc, Redwood City, CA, USA) and the Ion Endoluminal System (Intuitive Surgical, Sunnyvale, CA, USA), offering improved stability and distal airway visualization. As RAB adoption increases, there is a critical need for comparative effectiveness data of these systems to guide clinical decision-making and institutional investments. This study aims to compare the diagnostic yield and safety profiles of the Ion and Monarch RAB platforms after introduction at a single institution. <b>Methods</b>: We conducted a retrospective chart review of patients undergoing RAB in the first six months following the introduction of each platform. Demographic and radiographic data were collected. Diagnostic yield was defined as obtaining a malignant or specific benign diagnosis from bronchoscopy. <b>Results</b>: The study included 56 Ion and 36 Monarch procedures. Diagnostic yield was similar between Ion (75%) and Monarch (72%) groups (<i>p</i> = 0.8), with an adjusted odds ratio 0.89 (95% CI 0.30-2.72). Complications were low, with one pneumothorax occurring in each group. <b>Conclusions</b>: Early adoption and use of both RAB platforms suggests comparable diagnostic yields and safety profiles in our limited sample size. Larger studies including standardized anesthesia protocol and systematic use of real-time imaging are needed for further evaluation and comparative analysis.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-02-05
DOI
https://doi.org/10.3390/jcm15031284
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shape-Sensing Robotic-Assisted Bronchoscopy vs. Electromagnetic Robotic-Assisted Bronchoscopy—A Comparative Cohort Study

Joseph Cicenia, Y. Wang, Fatima Abdeljaleel, Graham Stockdale et al.
Journal of Clinical Medicine
Lung Cancer Diagnosis and Treatment
article

Shape-Sensing Robotic-Assisted Bronchoscopy vs. Electromagnetic Robotic-Assisted Bronchoscopy—A Comparative Cohort Study

Joseph Cicenia, Y. Wang, Fatima Abdeljaleel, Graham Stockdale, C. Yurosko, Colin T. Gillespie, B. Kemper, Michael Machuzak, SONALI SETHI, See-Wei Low, Xiaofeng Wang, Francisco Almeida, Thomas Gildea, Bryan S. Benn
article en

Abstract

<b>Introduction</b>: Lung cancer is a leading cause of cancer-related deaths globally, with approximately 1.5 million new peripheral pulmonary lesions (PPLs) detected annually in the United States. Robotic-assisted bronchoscopy (RAB) has emerged as a promising technology, with two platforms initially approved, the Monarch platform (Auris Health Inc, Redwood City, CA, USA) and the Ion Endoluminal System (Intuitive Surgical, Sunnyvale, CA, USA), offering improved stability and distal airway visualization. As RAB adoption increases, there is a critical need for comparative effectiveness data of these systems to guide clinical decision-making and institutional investments. This study aims to compare the diagnostic yield and safety profiles of the Ion and Monarch RAB platforms after introduction at a single institution. <b>Methods</b>: We conducted a retrospective chart review of patients undergoing RAB in the first six months following the introduction of each platform. Demographic and radiographic data were collected. Diagnostic yield was defined as obtaining a malignant or specific benign diagnosis from bronchoscopy. <b>Results</b>: The study included 56 Ion and 36 Monarch procedures. Diagnostic yield was similar between Ion (75%) and Monarch (72%) groups (<i>p</i> = 0.8), with an adjusted odds ratio 0.89 (95% CI 0.30-2.72). Complications were low, with one pneumothorax occurring in each group. <b>Conclusions</b>: Early adoption and use of both RAB platforms suggests comparable diagnostic yields and safety profiles in our limited sample size. Larger studies including standardized anesthesia protocol and systematic use of real-time imaging are needed for further evaluation and comparative analysis.

Journal of Clinical MedicineVol. 15(3)
Cleveland Clinic (US)
Cleveland Clinic, Cleveland Clinic Foundation
Openalex Percentile: Top 67%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.