Evaluation of Conventional and Electrostatic Sprayers for Decontamination of PPE-Covered Manikins

Following a bioterrorism event, an incident or unified command is established, the impacted area characterized, and response work zones set up based on the extent of indoor/outdoor contamination. The personnel decontamination line, established in the contamination reduction zone, is essential for ensuring potentially biohazardous contamination on worker personal protective equipment (PPE) does not migrate outside of this zone. During personnel decontamination, conventional backpack or portable garden-type sprayers are often used to distribute liquid decontaminant onto PPE surfaces to physically remove and/or inactivate the contaminant. This process can lead to migration of biological contaminants and produces large volumes of liquid waste. A comparison of the performance of electrostatic sprayers and conventional backpack sprayers in personnel biological decontamination revealed that the electrostatic sprayer generated substantially less liquid runoff (∼75X), which would minimize waste generation and disposal costs following an event. Pilot-scale tests using manikins with PPE showed decontamination efficacy greater than 6 log<sub>10</sub> reduction (liquid and aerosol inoculation of spores) for the conventional backpack sprayer while decontamination was effective but incomplete with the electrostatic sprayer (<6 log<sub>10</sub> reduction) with residual spores detected at "hard-to-reach" areas. Decontamination efficacy of the electrostatic sprayer was improved by increasing the spray time, as greater than 6 log<sub>10</sub> reduction was then observed (liquid and aerosol inoculation). Spore reaerosolization was higher during decontamination with the conventional backpack sprayer. The electrostatic sprayer as used in our study presents a viable decontamination option for a personnel decontamination line following biological agent contamination incidents.

Authors

Institutions

Publication Details

Journal
Health Security
Published
2026-02-06
DOI
https://doi.org/10.1177/23265094251413155
Primary Topic
Bacillus and Francisella bacterial research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Conventional and Electrostatic Sprayers for Decontamination of PPE-Covered Manikins

Michael Archer, Abderrahmane Touati, Ahmed Mohamed Abdel-Hady, Sang Don Lee et al.
Health Security
Bacillus and Francisella bacterial research
article

Evaluation of Conventional and Electrostatic Sprayers for Decontamination of PPE-Covered Manikins

Michael Archer, Abderrahmane Touati, Ahmed Mohamed Abdel-Hady, Sang Don Lee, Lukas Oudejans, R. Leroy Mickelsen, M. Worth Calfee
article en

Abstract

Following a bioterrorism event, an incident or unified command is established, the impacted area characterized, and response work zones set up based on the extent of indoor/outdoor contamination. The personnel decontamination line, established in the contamination reduction zone, is essential for ensuring potentially biohazardous contamination on worker personal protective equipment (PPE) does not migrate outside of this zone. During personnel decontamination, conventional backpack or portable garden-type sprayers are often used to distribute liquid decontaminant onto PPE surfaces to physically remove and/or inactivate the contaminant. This process can lead to migration of biological contaminants and produces large volumes of liquid waste. A comparison of the performance of electrostatic sprayers and conventional backpack sprayers in personnel biological decontamination revealed that the electrostatic sprayer generated substantially less liquid runoff (∼75X), which would minimize waste generation and disposal costs following an event. Pilot-scale tests using manikins with PPE showed decontamination efficacy greater than 6 log<sub>10</sub> reduction (liquid and aerosol inoculation of spores) for the conventional backpack sprayer while decontamination was effective but incomplete with the electrostatic sprayer (<6 log<sub>10</sub> reduction) with residual spores detected at "hard-to-reach" areas. Decontamination efficacy of the electrostatic sprayer was improved by increasing the spray time, as greater than 6 log<sub>10</sub> reduction was then observed (liquid and aerosol inoculation). Spore reaerosolization was higher during decontamination with the conventional backpack sprayer. The electrostatic sprayer as used in our study presents a viable decontamination option for a personnel decontamination line following biological agent contamination incidents.

Health Security
Soil Conservation and Watershed Management Research (IR)
Openalex Percentile: Top 66%
Bacillus and Francisella bacterial research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.