Reduction of heating energy demand by combining IR heaters and IR reflective walls: An experimental study

• Experiments in a climate chamber isolated the influence of IR heating power and surface emittance on thermal comfort. • Low surface emittance combined with IR heaters maximizes the use of thermal radiation and increases PMV. • High radiant temperatures achieved by low surface emittance allow for lower air temperatures and thus heating energy savings. • The response surface function from the experimental results can be used for IR heater control. In this study, we build upon previous simulation research that advocates the use of infrared (IR) heaters in conjunction with IR reflective interior walls to meet heating demand in buildings. This combination allows the walls to reflect the heat emitted by the IR heaters back to the occupants in a room, rather than absorbing the radiation. As a result, the radiant temperature increases and the air temperature can be lowered in order to maintain constant thermal comfort and to reduce heat loss through the building envelope. We conducted experiments in a climate chamber to isolate the effects of four factors on thermal comfort: the heating power of IR heaters, the IR emittance of the interior walls, the interior wall surface temperature, and the air temperature. The emittance was modified by applying an increasing number of adhesive aluminium foil stripes. Heat conduction through the wall to the outside is not part of this study. To minimize the number of required experiments, we employed a Central Composite Design, from which we derived a response surface function. The experimental results confirm a correlation between wall emittance and occupant thermal comfort in a room, particularly at higher IR heater power levels. The Predicted Mean Vote (PMV) value increases at lower wall emittance (corresponding to higher radiant temperatures), highlighting the potential for energy savings through reduced air temperatures. However, the observed impact of low emittance surfaces on the PMV is less pronounced than previously estimated in simulation studies.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2026-02-05
DOI
https://doi.org/10.1016/j.enbuild.2026.117112
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduction of heating energy demand by combining IR heaters and IR reflective walls: An experimental study

Kai Gehrke, Tobias Dehne, Bernhard Hoffschmidt, Björn Schiricke et al.
Energy and Buildings
Building Energy and Comfort Optimization
article

Reduction of heating energy demand by combining IR heaters and IR reflective walls: An experimental study

Kai Gehrke, Tobias Dehne, Bernhard Hoffschmidt, Björn Schiricke, Lukas Anselm Wille
article en

Abstract

• Experiments in a climate chamber isolated the influence of IR heating power and surface emittance on thermal comfort. • Low surface emittance combined with IR heaters maximizes the use of thermal radiation and increases PMV. • High radiant temperatures achieved by low surface emittance allow for lower air temperatures and thus heating energy savings. • The response surface function from the experimental results can be used for IR heater control. In this study, we build upon previous simulation research that advocates the use of infrared (IR) heaters in conjunction with IR reflective interior walls to meet heating demand in buildings. This combination allows the walls to reflect the heat emitted by the IR heaters back to the occupants in a room, rather than absorbing the radiation. As a result, the radiant temperature increases and the air temperature can be lowered in order to maintain constant thermal comfort and to reduce heat loss through the building envelope. We conducted experiments in a climate chamber to isolate the effects of four factors on thermal comfort: the heating power of IR heaters, the IR emittance of the interior walls, the interior wall surface temperature, and the air temperature. The emittance was modified by applying an increasing number of adhesive aluminium foil stripes. Heat conduction through the wall to the outside is not part of this study. To minimize the number of required experiments, we employed a Central Composite Design, from which we derived a response surface function. The experimental results confirm a correlation between wall emittance and occupant thermal comfort in a room, particularly at higher IR heater power levels. The Predicted Mean Vote (PMV) value increases at lower wall emittance (corresponding to higher radiant temperatures), highlighting the potential for energy savings through reduced air temperatures. However, the observed impact of low emittance surfaces on the PMV is less pronounced than previously estimated in simulation studies.

Energy and BuildingsVol. 357
Carl von Ossietzky Universität Oldenburg (DE), Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE), RWTH Aachen University (DE)
Deutsches Zentrum für Luft- und Raumfahrt
Affordable and clean energy
Openalex Percentile: Top 65%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.