Estimation of respiratory system parameters using an extended equation of motion during mandatory mechanical ventilation

Mechanical ventilation is crucial for critically-ill patients, but requires continuous adjustments to prevent injuries and ensure optimal performance. Accurate estimation of respiratory parameters is essential for guiding disease-specific ventilator adjustments and optimizing respiratory support. The traditional equation of motion (EOM), widely used for this purpose, assumes linear compliance and resistance and neglects key physiological phenomena such as flow-dependent resistance and viscoelasticity, which can lead to biased estimates. In this study, we propose and validate an extended equation of motion (EEOM) that integrates nonlinear resistance and viscoelastic effects into a single framework. We fit the EEOM to simulated data, experimental data with a test lung, and clinical patient data (N=10). The accuracy of the EEOM to measure airway resistance, compliance, and viscoelasticity was improved compared to the traditional models (EOM and turbulent EOM, TEOM). In simulations, EEOM method consistently reduced estimation errors across all scenarios. For example, in estimating compliance ( C rs ), EEOM achieved an average percentage error range of 0.06-1.18% across all scenarios, compared to 2.5–14.5% with EOM and 10.5–18.6% with TEOM. Across all parameters and simulations, EEOM yielded lower total mean absolute errors (3.5%) than EOM (11.5%) and TEOM (11.9%). In clinical data, EEOM estimates for viscoelastic parameters ( C d , R d ) were statistically comparable to the interrupter technique ( p > 0 . 05 ), additionally providing real-time estimates for nonlinear resistance terms. These results demonstrate that extended mechanical parameters, including nonlinear resistance and viscoelasticity, can be identified noninvasively using standard ventilator signals, enabling more personalized, safer and adaptive ventilator settings. • An extended equation of motion integrates nonlinear resistance and viscoelasticity. • Extended modeling reduces errors in compliance and resistance estimation across datasets. • Respiratory mechanics are estimated noninvasively using standard ventilator signals.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-02-05
DOI
https://doi.org/10.1016/j.bspc.2026.109770
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of respiratory system parameters using an extended equation of motion during mandatory mechanical ventilation

Anouk van Diepen, A.J.R. de Bie, Massimo Mischi, Simona Turco et al.
Biomedical Signal Processing and Control
Respiratory Support and Mechanisms
article

Estimation of respiratory system parameters using an extended equation of motion during mandatory mechanical ventilation

Anouk van Diepen, A.J.R. de Bie, Massimo Mischi, Simona Turco, R.A. Bouwman, T.H.G.F. Bakkes, P.H. Woerlee
article en

Abstract

Mechanical ventilation is crucial for critically-ill patients, but requires continuous adjustments to prevent injuries and ensure optimal performance. Accurate estimation of respiratory parameters is essential for guiding disease-specific ventilator adjustments and optimizing respiratory support. The traditional equation of motion (EOM), widely used for this purpose, assumes linear compliance and resistance and neglects key physiological phenomena such as flow-dependent resistance and viscoelasticity, which can lead to biased estimates. In this study, we propose and validate an extended equation of motion (EEOM) that integrates nonlinear resistance and viscoelastic effects into a single framework. We fit the EEOM to simulated data, experimental data with a test lung, and clinical patient data (N=10). The accuracy of the EEOM to measure airway resistance, compliance, and viscoelasticity was improved compared to the traditional models (EOM and turbulent EOM, TEOM). In simulations, EEOM method consistently reduced estimation errors across all scenarios. For example, in estimating compliance ( C rs ), EEOM achieved an average percentage error range of 0.06-1.18% across all scenarios, compared to 2.5–14.5% with EOM and 10.5–18.6% with TEOM. Across all parameters and simulations, EEOM yielded lower total mean absolute errors (3.5%) than EOM (11.5%) and TEOM (11.9%). In clinical data, EEOM estimates for viscoelastic parameters ( C d , R d ) were statistically comparable to the interrupter technique ( p > 0 . 05 ), additionally providing real-time estimates for nonlinear resistance terms. These results demonstrate that extended mechanical parameters, including nonlinear resistance and viscoelasticity, can be identified noninvasively using standard ventilator signals, enabling more personalized, safer and adaptive ventilator settings. • An extended equation of motion integrates nonlinear resistance and viscoelasticity. • Extended modeling reduces errors in compliance and resistance estimation across datasets. • Respiratory mechanics are estimated noninvasively using standard ventilator signals.

Biomedical Signal Processing and ControlVol. 118
Radboud University Nijmegen (NL), Catharina Ziekenhuis (NL), Eindhoven University of Technology (NL)
Good health and well-being
Openalex Percentile: Top 67%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.