Role of HVAC in building energy consumption: a critical review

Abstract This review critically evaluates the energy performance of diverse HVAC systems, with a focus on their quantified consumption profiles and operational efficiencies across varying climatic zones and building types. Conventional split air conditioning units were observed to have the highest energy demand, reaching up to 18,549.6 kWh month −1 in university buildings, with air conditioning accounting for over 80% of total electricity use. In contrast, variable refrigerant flow (VRF) systems demonstrated superior part-load efficiency, with monthly consumption reduced to 9626.9 kWh and energy performance indices (ENPI) improved by 36.6%. Ground source heat pumps (GSHPs) operating under stable subsurface conditions achieved thermal outputs of 7.0–16.0 kW with COP values ranging from 1.34 to 4.7, while hybrid systems integrating desiccant wheels and evaporative cooling reported cooling capacities between 0.84 and 16.9 kW, and COPs reaching up to 35.2 under optimised conditions. Photovoltaic-assisted systems were capable of offsetting up to 80% of cooling energy demand, equating to approximately 3.5–4.0 kWh/day savings in residential settings. Control strategies such as night purge and adaptive setpoint scheduling yielded energy reductions of 17–26%, and the integration of economisers led to a 25.5% drop in total HVAC consumption. Advanced predictive models incorporating artificial intelligence achieved accuracy levels exceeding R 2 = 0.98 across simulations of over 250,000 scenarios. These findings collectively underline the critical importance of selecting context-appropriate HVAC technologies and implementing intelligent, climate-responsive control to achieve substantial reductions in system loads, power input, and operational energy demand, thereby supporting global efforts towards sustainable and low-carbon buildings.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Analysis and Calorimetry
Published
2026-02-01
DOI
https://doi.org/10.1007/s10973-026-15322-9
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of HVAC in building energy consumption: a critical review

Erdem Cuce, Pinar Mert Cuce
Journal of Thermal Analysis and Calorimetry
Adsorption and Cooling Systems
article

Role of HVAC in building energy consumption: a critical review

Erdem Cuce, Pinar Mert Cuce
article en

Abstract

Abstract This review critically evaluates the energy performance of diverse HVAC systems, with a focus on their quantified consumption profiles and operational efficiencies across varying climatic zones and building types. Conventional split air conditioning units were observed to have the highest energy demand, reaching up to 18,549.6 kWh month −1 in university buildings, with air conditioning accounting for over 80% of total electricity use. In contrast, variable refrigerant flow (VRF) systems demonstrated superior part-load efficiency, with monthly consumption reduced to 9626.9 kWh and energy performance indices (ENPI) improved by 36.6%. Ground source heat pumps (GSHPs) operating under stable subsurface conditions achieved thermal outputs of 7.0–16.0 kW with COP values ranging from 1.34 to 4.7, while hybrid systems integrating desiccant wheels and evaporative cooling reported cooling capacities between 0.84 and 16.9 kW, and COPs reaching up to 35.2 under optimised conditions. Photovoltaic-assisted systems were capable of offsetting up to 80% of cooling energy demand, equating to approximately 3.5–4.0 kWh/day savings in residential settings. Control strategies such as night purge and adaptive setpoint scheduling yielded energy reductions of 17–26%, and the integration of economisers led to a 25.5% drop in total HVAC consumption. Advanced predictive models incorporating artificial intelligence achieved accuracy levels exceeding R 2 = 0.98 across simulations of over 250,000 scenarios. These findings collectively underline the critical importance of selecting context-appropriate HVAC technologies and implementing intelligent, climate-responsive control to achieve substantial reductions in system loads, power input, and operational energy demand, thereby supporting global efforts towards sustainable and low-carbon buildings.

Journal of Thermal Analysis and CalorimetryVol. 151(4)
Chandigarh University (IN), Birmingham City University (GB), Recep Tayyip Erdoğan University (TR), Chitkara University (IN)
Affordable and clean energy
Openalex Percentile: Top 66%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.