Formaldehyde releasers in cleaning products: Mapping an indoor issue

Formaldehyde releasers are widely employed in household cleaning products as preservatives and biocidal agents, emerging as indirect sources of formaldehyde in indoor environments. Despite their prevalence, knowledge regarding their occurrence, degradation pathways, and contribution to indoor formaldehyde exposure remains scattered. This review synthesizes current understanding of formaldehyde releasers in household products, focusing on major global regulatory frameworks, chemical properties, modes of action, and associated analytical challenges. Bronopol, the most frequently encountered releaser in cleaning products, illustrates the dual role of these compounds: it exhibits direct biocidal activity and releases formaldehyde through degradation in aqueous media, a process influenced by pH, temperature, and the presence of other formulation components. Analytical methods, allow quantification of releasers and some degradation products, yet no method enables simultaneous, accurate measurement of both releasers and the formaldehyde released, limiting the characterization of emission kinetics. Experimental data on indoor formaldehyde emissions from household products are extremely limited; available studies indicate rapid initial release followed by quasi-steady emissions, demonstrating potential for long-term indoor exposure. Key knowledge gaps remain regarding the relationship between releaser concentration, degradation dynamics, and actual emissions in realistic use scenarios, including the fate of releasers on surfaces and their multi-phasic behaviour, based on specific analytical developments. Addressing these gaps is critical to evaluate exposure risks, guide regulatory strategies, and inform the development of safer household formulations. This review highlights the urgent need for integrated analytical and experimental approaches to quantify and understand the indoor impact of formaldehyde releasers.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials
Published
2026-02-01
DOI
https://doi.org/10.1016/j.jhazmat.2026.141393
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Formaldehyde releasers in cleaning products: Mapping an indoor issue

Shadia Angulo-Milhem, Frédéric Thévenet, Marie Verrièle, Gabriel Rossignol et al.
Journal of Hazardous Materials
Indoor Air Quality and Microbial Exposure
article

Formaldehyde releasers in cleaning products: Mapping an indoor issue

Shadia Angulo-Milhem, Frédéric Thévenet, Marie Verrièle, Gabriel Rossignol, Mélanie Nicolas
article en

Abstract

Formaldehyde releasers are widely employed in household cleaning products as preservatives and biocidal agents, emerging as indirect sources of formaldehyde in indoor environments. Despite their prevalence, knowledge regarding their occurrence, degradation pathways, and contribution to indoor formaldehyde exposure remains scattered. This review synthesizes current understanding of formaldehyde releasers in household products, focusing on major global regulatory frameworks, chemical properties, modes of action, and associated analytical challenges. Bronopol, the most frequently encountered releaser in cleaning products, illustrates the dual role of these compounds: it exhibits direct biocidal activity and releases formaldehyde through degradation in aqueous media, a process influenced by pH, temperature, and the presence of other formulation components. Analytical methods, allow quantification of releasers and some degradation products, yet no method enables simultaneous, accurate measurement of both releasers and the formaldehyde released, limiting the characterization of emission kinetics. Experimental data on indoor formaldehyde emissions from household products are extremely limited; available studies indicate rapid initial release followed by quasi-steady emissions, demonstrating potential for long-term indoor exposure. Key knowledge gaps remain regarding the relationship between releaser concentration, degradation dynamics, and actual emissions in realistic use scenarios, including the fate of releasers on surfaces and their multi-phasic behaviour, based on specific analytical developments. Addressing these gaps is critical to evaluate exposure risks, guide regulatory strategies, and inform the development of safer household formulations. This review highlights the urgent need for integrated analytical and experimental approaches to quantify and understand the indoor impact of formaldehyde releasers.

Journal of Hazardous MaterialsVol. 504
Centre Scientifique et Technique du Bâtiment (FR), Centre Inria de l'Université de Lille (FR), Université Lille Nord de France (FR)
Openalex Percentile: Top 68%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.