Spatiotemporal Interactive Effects Between Thermal Comfort and Acoustic Quality on University Students’ Performance and Satisfaction in Hong Kong

This study investigated the individual and interactive effects of thermal and acoustic parameters on university students’ concentration and satisfaction in a library environment. Measurements of temperature, relative humidity (RH), and sound pressure level (SPL), alongside questionnaire surveys assessing students’ concentration, environmental perceptions, and satisfaction, were conducted over ten continuous working days in four library rooms. The results revealed significant interactive effects between operative temperature (To), RH, and background noise level (LA90) on students’ concentration and overall satisfaction, highlighting the importance of an integrated approach to managing Indoor Environmental Quality (IEQ). Furthermore, multi-objective optimization using the NSGA-II algorithm suggested optimal ranges for To (22.6–24.8 °C), RH (41.0–48.4%), and LA90 (45.0–48.5 dB(A)). Existing library conditions surpassed these optimal levels, particularly on the first floor, indicating a pressing need for interventions to enhance student well-being and academic performance. Overall, this study provides insights into the interactions between thermal comfort and acoustic quality, offering recommendations for creating more conducive learning environments that boost student satisfaction and performance.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-02-05
DOI
https://doi.org/10.3390/buildings16030670
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatiotemporal Interactive Effects Between Thermal Comfort and Acoustic Quality on University Students’ Performance and Satisfaction in Hong Kong

Dadi Zhang, Kwok-Wai Mui, Amneh Hamida, Ling-Tim Wong
Buildings
Indoor Air Quality and Microbial Exposure
article

Spatiotemporal Interactive Effects Between Thermal Comfort and Acoustic Quality on University Students’ Performance and Satisfaction in Hong Kong

Dadi Zhang, Kwok-Wai Mui, Amneh Hamida, Ling-Tim Wong
article en

Abstract

This study investigated the individual and interactive effects of thermal and acoustic parameters on university students’ concentration and satisfaction in a library environment. Measurements of temperature, relative humidity (RH), and sound pressure level (SPL), alongside questionnaire surveys assessing students’ concentration, environmental perceptions, and satisfaction, were conducted over ten continuous working days in four library rooms. The results revealed significant interactive effects between operative temperature (To), RH, and background noise level (LA90) on students’ concentration and overall satisfaction, highlighting the importance of an integrated approach to managing Indoor Environmental Quality (IEQ). Furthermore, multi-objective optimization using the NSGA-II algorithm suggested optimal ranges for To (22.6–24.8 °C), RH (41.0–48.4%), and LA90 (45.0–48.5 dB(A)). Existing library conditions surpassed these optimal levels, particularly on the first floor, indicating a pressing need for interventions to enhance student well-being and academic performance. Overall, this study provides insights into the interactions between thermal comfort and acoustic quality, offering recommendations for creating more conducive learning environments that boost student satisfaction and performance.

BuildingsVol. 16(3)
Hong Kong Polytechnic University (HK), RWTH Aachen University (DE)
Hong Kong Polytechnic University
Openalex Percentile: Top 68%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.