Clinical Decision-Making in High-Risk Cross-Platform Redo-TAVI: Pre-Emptive Coronary Wiring and Chimney Stenting

Background: Redo transcatheter aortic valve implantation (TAVI) in patients with prior transapical SAPIEN 3 valves carries a significant risk of coronary obstruction. Chimney stenting is an established strategy to maintain coronary perfusion in high-risk valve-in-valve (ViV) procedures. Case Description: An 87-year-old woman presented with NYHA class IV symptoms due to severe restenosis of a 20-mm SAPIEN 3 valve implanted in 2017. Computed tomography revealed stent extension beyond the sinotubular junction, posing a risk of right coronary artery (RCA) occlusion. A transfemoral redo-TAVI using a 23-mm Medtronic Evolut FX+ valve was performed with pre-positioned chimney stenting. During valve deployment, inferior ST-segment elevation occurred, necessitating immediate RCA stenting. A second distal RCA stent addressed residual stenosis. Final angiography confirmed preserved coronary flow and optimal valve function; Discussion: Careful preprocedural evaluation—including CT-based assessment of coronary height, sinus anatomy, and virtual valve modeling—is essential in high-risk ViV or redo-TAVI cases. The chimney technique provides an effective bailout for acute coronary obstruction, while procedural strategies such as commissural alignment and the cusp-overlap technique can optimize procedural and hemodynamic outcomes.; Conclusions: Planned coronary protection using chimney stenting enables safe and effective redo transfemoral TAVI in patients with complex anatomy and prior transapical valve implantation, ensuring hemodynamic success and minimizing complications.

Authors

Institutions

Publication Details

Journal
Cardiovascular Medicine
Published
2026-11-04
DOI
https://doi.org/10.3390/cardiovascmed29040042
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Decision-Making in High-Risk Cross-Platform Redo-TAVI: Pre-Emptive Coronary Wiring and Chimney Stenting

Davor Vukadinović, Alexander Staudt, Christian D. Etz, Marcus-André Deutsch et al.
4 links
Cardiovascular Medicine
Cardiac Valve Diseases and Treatments
article

Clinical Decision-Making in High-Risk Cross-Platform Redo-TAVI: Pre-Emptive Coronary Wiring and Chimney Stenting

Davor Vukadinović, Alexander Staudt, Christian D. Etz, Marcus-André Deutsch, Vladyslav Kavalerchyk, Magdalena Sikole, Hristijan Alagjozovski, Ahmed Saleh Abu Rumman, Sasho Stanisavljevikj, Christian Jacob, Jens Papenefuss, Christian Fahje Klopsch, Ivica Bojovski
article en

Abstract

Background: Redo transcatheter aortic valve implantation (TAVI) in patients with prior transapical SAPIEN 3 valves carries a significant risk of coronary obstruction. Chimney stenting is an established strategy to maintain coronary perfusion in high-risk valve-in-valve (ViV) procedures. Case Description: An 87-year-old woman presented with NYHA class IV symptoms due to severe restenosis of a 20-mm SAPIEN 3 valve implanted in 2017. Computed tomography revealed stent extension beyond the sinotubular junction, posing a risk of right coronary artery (RCA) occlusion. A transfemoral redo-TAVI using a 23-mm Medtronic Evolut FX+ valve was performed with pre-positioned chimney stenting. During valve deployment, inferior ST-segment elevation occurred, necessitating immediate RCA stenting. A second distal RCA stent addressed residual stenosis. Final angiography confirmed preserved coronary flow and optimal valve function; Discussion: Careful preprocedural evaluation—including CT-based assessment of coronary height, sinus anatomy, and virtual valve modeling—is essential in high-risk ViV or redo-TAVI cases. The chimney technique provides an effective bailout for acute coronary obstruction, while procedural strategies such as commissural alignment and the cusp-overlap technique can optimize procedural and hemodynamic outcomes.; Conclusions: Planned coronary protection using chimney stenting enables safe and effective redo transfemoral TAVI in patients with complex anatomy and prior transapical valve implantation, ensuring hemodynamic success and minimizing complications.

Cardiovascular MedicineVol. 29(4)
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Heart and Diabetes Center North Rhine-Westphalia (DE), MSH Medical School Hamburg – University of Applied Sciences and Medical University (DE), Universitätsklinikum des Saarlandes (DE), Helios Hospital Schwerin (DE), University of Rostock (DE), Ss. Cyril and Methodius University in Skopje (MK)
Good health and well-being
Openalex Percentile: Top 93%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon