Stability indicating chromatographic method development and validation for acotiamide HCl trihydrate with comprehensive forced degradation studies and LCMS/MS characterization of related substances

A newly developed stability-indicating reversed-phase high-performance liquid chromatography method was validated for the simultaneous quantification of assay and related substances of Acotiamide Hydrochloride Trihydrate, a gastroprokinetic drug, in pharmaceutical dosage forms. The aim of the study was to establish a simple, rapid, precise, accurate, and cost-effective chromatographic method capable of detecting degradation products through forced degradation studies. Chromatographic separation was achieved using an Inertsil ODS-3 V column (150 mm × 4.6 mm, 5 μm), with a mobile phase comprising methanol and ammonium acetate buffer (pH 6.8) in the ratio of 55:45 (v/v), at a flow rate of 2.0 mL/min. Detection was performed with a photodiode array detector at 280 nm. Validation, as per the International Council for Harmonisation guideline Q2 (R2), demonstrated excellent specificity, linearity (correlation coefficient > 0.999), accuracy (98–102% for the assay), precision (relative standard deviation < 2%), and robustness under variable analytical conditions. The method effectively separated Acotiamide from its degradation products. Forced degradation studies revealed significant degradation under basic and oxidative conditions, while stability was observed under acidic, thermal, and photolytic conditions. A major degradation product observed in basic and oxidative conditions, eluting at 9.5 min, was identified using a TSQ Endura Triple Quadrupole Mass Spectrometer and characterized as 2-[(1,2-dihydroxy-5,6-dimethoxybenzamido)-N-(2-(diisopropylamino) ethyl)-N-hydroxythiazole-4-carboxamide], with prominent mass fragmentation observed at m/z 467. The validated method is suitable for routine quality control and stability assessment of Acotiamide Hydrochloride Trihydrate.

Authors

Institutions

Publication Details

Journal
Discover Chemistry.
Published
2026-02-04
DOI
https://doi.org/10.1007/s44371-026-00494-y
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability indicating chromatographic method development and validation for acotiamide HCl trihydrate with comprehensive forced degradation studies and LCMS/MS characterization of related substances

Vijay Arjun Bagul, Poonam Prakash Patil, Suryakant D. Bhosle, Bhushan Balkrushna Gangurde et al.
Discover Chemistry.
Analytical Methods in Pharmaceuticals
article

Stability indicating chromatographic method development and validation for acotiamide HCl trihydrate with comprehensive forced degradation studies and LCMS/MS characterization of related substances

Vijay Arjun Bagul, Poonam Prakash Patil, Suryakant D. Bhosle, Bhushan Balkrushna Gangurde, Santosh B. Katariya
article en

Abstract

A newly developed stability-indicating reversed-phase high-performance liquid chromatography method was validated for the simultaneous quantification of assay and related substances of Acotiamide Hydrochloride Trihydrate, a gastroprokinetic drug, in pharmaceutical dosage forms. The aim of the study was to establish a simple, rapid, precise, accurate, and cost-effective chromatographic method capable of detecting degradation products through forced degradation studies. Chromatographic separation was achieved using an Inertsil ODS-3 V column (150 mm × 4.6 mm, 5 μm), with a mobile phase comprising methanol and ammonium acetate buffer (pH 6.8) in the ratio of 55:45 (v/v), at a flow rate of 2.0 mL/min. Detection was performed with a photodiode array detector at 280 nm. Validation, as per the International Council for Harmonisation guideline Q2 (R2), demonstrated excellent specificity, linearity (correlation coefficient > 0.999), accuracy (98–102% for the assay), precision (relative standard deviation < 2%), and robustness under variable analytical conditions. The method effectively separated Acotiamide from its degradation products. Forced degradation studies revealed significant degradation under basic and oxidative conditions, while stability was observed under acidic, thermal, and photolytic conditions. A major degradation product observed in basic and oxidative conditions, eluting at 9.5 min, was identified using a TSQ Endura Triple Quadrupole Mass Spectrometer and characterized as 2-[(1,2-dihydroxy-5,6-dimethoxybenzamido)-N-(2-(diisopropylamino) ethyl)-N-hydroxythiazole-4-carboxamide], with prominent mass fragmentation observed at m/z 467. The validated method is suitable for routine quality control and stability assessment of Acotiamide Hydrochloride Trihydrate.

Discover Chemistry.Vol. 3(1)
Homi Bhabha National Institute (IN), Department of Commerce (AU), Institute of Engineering (NP), Hindu College of Pharmacy (IN)
Openalex Percentile: Top 64%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.