Deep learning-based one-stop 11C-CFT and 18F-FDG dual-tracer brain PET imaging protocol for Parkinson’s disease

This study explored using deep learning (DL) to separate short-interval staggered <sup>11</sup>C-CFT/<sup>18</sup>F-FDG brain PET images for Parkinson's disease, aiming to reduce scan waiting time. A total of 67 patients performing <sup>11</sup>C-CFT and <sup>18</sup>F-FDG brain PET scans on separate days were retrospectively enrolled. A Swin UNETR model was trained to generate pseudo <sup>18</sup>F-FDG PET images from simulated dual-tracer sum images. The simulation assumed <sup>18</sup>F-FDG was administered at 80, 100, 120, or 200 min (∆t) after <sup>11</sup>C-CFT injection. Compared to actual <sup>18</sup>F-FDG images, the pseudo images showed high visual similarity across all ∆t intervals. Low average NMSE values (∼0.0004) and high average SSIM values (0.9991-0.9993) were consistently achieved across all Δt groups. Bland & Altman analysis of the whole brain region demonstrated low average SUVR bias across all Δt groups remained within ±0.001. Region-wise correlation analysis revealed strong correlations between actual and pseudo <sup>18</sup>F-FDG images across all Δt, with slopes ranging from 0.994 to 1.001, and all R<sup>2</sup>> 0.99. SUVmean, LBR and SNR values for pseudo <sup>18</sup>F-FDG images exhibited no statistically significant differences compared to actual <sup>18</sup>F-FDG images (P > 0.05). Dual-tracer PET images can be effectively separated using the DL model, yielding high-quality visual and semi-quantitative results when <sup>18</sup>F-FDG is injected immediately after the <sup>11</sup>C-CFT PET scan, thereby reducing patient wait time, improving patient comfort, and enhancing overall clinical efficiency.

Authors

Institutions

Publication Details

Journal
Brain Research Bulletin
Published
2026-02-04
DOI
https://doi.org/10.1016/j.brainresbull.2026.111764
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning-based one-stop 11C-CFT and 18F-FDG dual-tracer brain PET imaging protocol for Parkinson’s disease

Xiaoyue Tan, Fanghu Wang, Xiaolin Sun, Shanzhen He et al.
Brain Research Bulletin
Medical Imaging Techniques and Applications
article

Deep learning-based one-stop 11C-CFT and 18F-FDG dual-tracer brain PET imaging protocol for Parkinson’s disease

Xiaoyue Tan, Fanghu Wang, Xiaolin Sun, Shanzhen He, Lei Jiang, Yuan Chang, Hao Sun, Qing Zhang, Lijun Lu
article en

Abstract

This study explored using deep learning (DL) to separate short-interval staggered <sup>11</sup>C-CFT/<sup>18</sup>F-FDG brain PET images for Parkinson's disease, aiming to reduce scan waiting time. A total of 67 patients performing <sup>11</sup>C-CFT and <sup>18</sup>F-FDG brain PET scans on separate days were retrospectively enrolled. A Swin UNETR model was trained to generate pseudo <sup>18</sup>F-FDG PET images from simulated dual-tracer sum images. The simulation assumed <sup>18</sup>F-FDG was administered at 80, 100, 120, or 200 min (∆t) after <sup>11</sup>C-CFT injection. Compared to actual <sup>18</sup>F-FDG images, the pseudo images showed high visual similarity across all ∆t intervals. Low average NMSE values (∼0.0004) and high average SSIM values (0.9991-0.9993) were consistently achieved across all Δt groups. Bland & Altman analysis of the whole brain region demonstrated low average SUVR bias across all Δt groups remained within ±0.001. Region-wise correlation analysis revealed strong correlations between actual and pseudo <sup>18</sup>F-FDG images across all Δt, with slopes ranging from 0.994 to 1.001, and all R<sup>2</sup>> 0.99. SUVmean, LBR and SNR values for pseudo <sup>18</sup>F-FDG images exhibited no statistically significant differences compared to actual <sup>18</sup>F-FDG images (P > 0.05). Dual-tracer PET images can be effectively separated using the DL model, yielding high-quality visual and semi-quantitative results when <sup>18</sup>F-FDG is injected immediately after the <sup>11</sup>C-CFT PET scan, thereby reducing patient wait time, improving patient comfort, and enhancing overall clinical efficiency.

Brain Research BulletinVol. 236
Guangdong Academy of Medical Sciences (CN), Guangdong Provincial People's Hospital (CN), Southern Medical University (CN)
Openalex Percentile: Top 67%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.