Biomechanical study on the treatment of tibial defects in total knee arthroplasty using the cement-screw and metal block with extension stem techniques: a finite element analysis
The findings of this study indicate that the cement-screw technique is more cost-effective and convenient for repairing 5-mm defects and is appropriate for reconstruction of this size. However, when the bone defect reaches 10 mm, the cement-screw technique may elevate the risk of fracture, and thus, safety concerns must be taken into account. In contrast, the metal block extension stem technique offers a better balance between effectiveness and safety, making it the preferred option for defects of this size.
Authors
- Gang Duan
- Zhexi Zhu
- Qiang Gu
- Ziqiang Zhu
- Yafei Lu
- Wenrui Liu
Institutions
- Hebei Medical University (CN)
- Xuzhou Medical College (CN)
- Peking University (CN)
- Peking University People's Hospital (CN)
- Second Affiliated Hospital of Xuzhou Medical College (CN)
Publication Details
- Journal
- Frontiers in Bioengineering and Biotechnology
- Published
- 2026-02-04
- DOI
- https://doi.org/10.3389/fbioe.2026.1721687
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Government of Jiangsu Province
- Xuzhou Science and Technology Program