The Application of a Non-Newtonian Fluid as a Protective Layer for a CFRP Material Subjected to Low-Energy Impact Loads

One of the key challenges in using CFRP (Carbon Fiber Reinforced Polymer) structures is their susceptibility to low-energy impact damage, often indicated as barely visible impact damage (BVID). Such defects are difficult to detect and can compromise structural integrity. This study investigates the use of immobilized non-Newtonian fluids (NNF) as protective layers for CFRP composites subjected to low-energy impacts. Experimental tests were carried out with an Instron 9440 drop-weight impact tower (impact energy range 5-40 J) and high-speed imaging, comparing NNF coatings with rubber-based, caoutchouc-based, and spray-based protective layers. Non-destructive evaluation using computed tomography confirmed that NNF coatings dissipate impact energy through shear-thickening behavior, reducing delamination while preserving clear visual indicators of the impact site. Furthermore, the study assessed post-impact fatigue bending performance, revealing that the inclusion of NNF-either as an outer layer or as part of a sandwich structure-significantly enhanced the residual fatigue strength of the composites. Moreover, NNFs inherently preserve visible traces of penetration, thereby improving the detectability of impact locations through both unaided visual inspection and advanced imaging modalities such as computed tomography. In addition to external coatings, NNF was applied as a core in sandwich structures, demonstrating improved impact resistance compared to monolithic CFRP laminates and conventional CFRP-foam sandwiches. The protective performance was found to depend on fluid thickness and threshold shear rates required for viscosity transition, indicating that thicker layers do not always provide superior protection.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-02-04
DOI
https://doi.org/10.3390/ma19030606
Primary Topic
Mechanical Behavior of Composites
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Application of a Non-Newtonian Fluid as a Protective Layer for a CFRP Material Subjected to Low-Energy Impact Loads

Angelika Arkuszyńska, Marek Rośkowicz, Piotr Arkuszyński
Materials
Mechanical Behavior of Composites
article

The Application of a Non-Newtonian Fluid as a Protective Layer for a CFRP Material Subjected to Low-Energy Impact Loads

Angelika Arkuszyńska, Marek Rośkowicz, Piotr Arkuszyński
article en

Abstract

One of the key challenges in using CFRP (Carbon Fiber Reinforced Polymer) structures is their susceptibility to low-energy impact damage, often indicated as barely visible impact damage (BVID). Such defects are difficult to detect and can compromise structural integrity. This study investigates the use of immobilized non-Newtonian fluids (NNF) as protective layers for CFRP composites subjected to low-energy impacts. Experimental tests were carried out with an Instron 9440 drop-weight impact tower (impact energy range 5-40 J) and high-speed imaging, comparing NNF coatings with rubber-based, caoutchouc-based, and spray-based protective layers. Non-destructive evaluation using computed tomography confirmed that NNF coatings dissipate impact energy through shear-thickening behavior, reducing delamination while preserving clear visual indicators of the impact site. Furthermore, the study assessed post-impact fatigue bending performance, revealing that the inclusion of NNF-either as an outer layer or as part of a sandwich structure-significantly enhanced the residual fatigue strength of the composites. Moreover, NNFs inherently preserve visible traces of penetration, thereby improving the detectability of impact locations through both unaided visual inspection and advanced imaging modalities such as computed tomography. In addition to external coatings, NNF was applied as a core in sandwich structures, demonstrating improved impact resistance compared to monolithic CFRP laminates and conventional CFRP-foam sandwiches. The protective performance was found to depend on fluid thickness and threshold shear rates required for viscosity transition, indicating that thicker layers do not always provide superior protection.

MaterialsVol. 19(3)
Military University of Technology in Warsaw (PL)
Wojskowa Akademia Techniczna
Affordable and clean energy
Openalex Percentile: Top 66%
Mechanical Behavior of Composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Application of a Non-Newtonian Fluid as a Protective Layer for a CFRP Material Subjected to Low-Energy Impact Loads — Angelika Arkuszyńska, Marek Rośkowicz, et al. · Materials (2026) | TGRS Research Map | TGRS