pH-Dependent Long-Term Degradation and Mechanical Integrity of LPBF-Fabricated Porous Ti-6Al-4V in Hank’s Solutions with Different pH Values

Titanium alloys are widely used as bone graft materials due to their excellent corrosion resistance and biocompatibility. Implant failure can result from long-term exposure to body fluids and inflammation-induced pH decreases, both of which compromise the material’s corrosion resistance and mechanical stability. To address this issue, porous Ti-6Al-4V alloy was selected in this work. Immersion tests were conducted in Hank’s solution with different pH values (3, 5, and 7) for 90 days to simulate the in vivo microenvironment under various physiological conditions. The degradation behavior of porous Ti-6Al-4V alloy during the 90-day immersion period was systematically investigated using a combination of characterization techniques. The results indicated that TiO2, Ca3(PO4)2, and Ca(H2PO4)2 phases were formed on the surface of the after 90 days of immersion. Massive dissolution of TiO2 was observed in solutions with high H+ concentration (low pH). Ion release tests revealed that the concentration of titanium ions released was significantly higher in acidic solutions, suggesting that the passive film formed on porous Ti-6Al-4V alloy was unstable and prone to dissolution under acidic conditions. Consequently, a large amount of corrosion products accumulated on the specimen surfaces immersed in acidic solutions for a long duration. Moreover, the compression properties of the samples deteriorated after immersion. Specifically, the compressive strength decreased by 12.68 MPa, 11.67 MPa, and 5.84 MPa for sample immersed in solutions with pH = 3, 5, and 7, respectively. The significant reduction in compressive performance of the alloy in high H+ concentration solutions was attributed to the decreased compactness caused by ion release. The fracture mode of the porous Ti-6Al-4V alloy after immersion was identified as a mixed mode of ductile and brittle fracture.

Authors

Institutions

Publication Details

Journal
Metals
Published
2026-02-04
DOI
https://doi.org/10.3390/met16020187
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

pH-Dependent Long-Term Degradation and Mechanical Integrity of LPBF-Fabricated Porous Ti-6Al-4V in Hank’s Solutions with Different pH Values

Sheng Lu, Zhenyu Xiao, Dubovyy Oleksandr, Liang-Yu Chen et al.
Metals
Titanium Alloys Microstructure and Properties
article

pH-Dependent Long-Term Degradation and Mechanical Integrity of LPBF-Fabricated Porous Ti-6Al-4V in Hank’s Solutions with Different pH Values

Sheng Lu, Zhenyu Xiao, Dubovyy Oleksandr, Liang-Yu Chen, Wei-Gang Lv
article en

Abstract

Titanium alloys are widely used as bone graft materials due to their excellent corrosion resistance and biocompatibility. Implant failure can result from long-term exposure to body fluids and inflammation-induced pH decreases, both of which compromise the material’s corrosion resistance and mechanical stability. To address this issue, porous Ti-6Al-4V alloy was selected in this work. Immersion tests were conducted in Hank’s solution with different pH values (3, 5, and 7) for 90 days to simulate the in vivo microenvironment under various physiological conditions. The degradation behavior of porous Ti-6Al-4V alloy during the 90-day immersion period was systematically investigated using a combination of characterization techniques. The results indicated that TiO2, Ca3(PO4)2, and Ca(H2PO4)2 phases were formed on the surface of the after 90 days of immersion. Massive dissolution of TiO2 was observed in solutions with high H+ concentration (low pH). Ion release tests revealed that the concentration of titanium ions released was significantly higher in acidic solutions, suggesting that the passive film formed on porous Ti-6Al-4V alloy was unstable and prone to dissolution under acidic conditions. Consequently, a large amount of corrosion products accumulated on the specimen surfaces immersed in acidic solutions for a long duration. Moreover, the compression properties of the samples deteriorated after immersion. Specifically, the compressive strength decreased by 12.68 MPa, 11.67 MPa, and 5.84 MPa for sample immersed in solutions with pH = 3, 5, and 7, respectively. The significant reduction in compressive performance of the alloy in high H+ concentration solutions was attributed to the decreased compactness caused by ion release. The fracture mode of the porous Ti-6Al-4V alloy after immersion was identified as a mixed mode of ductile and brittle fracture.

MetalsVol. 16(2)
Admiral Makarov National University of Shipbuilding (UA), Jiangsu University of Science and Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 67%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.