Gallium Oxide-Based Photodetectors for Water Quality Monitoring

We present an approach to water quality monitoring using gallium oxide (Ga<sub>2</sub>O<sub>3</sub>) ultrawide-band-gap semiconductors. Nitrates, dissolved organic carbon, and suspended solid concentrations are three commonly measured water quality parameters that display optical absorption ranging from the deep ultraviolet to the visible region. This broad spectral region poses a challenge for accurate and efficient (simultaneous) measurement of absorption/extinction arising from varying concentrations of these parameters because silicon (Si), the classical detector material, has poor performance across this optical region. To overcome these limitations, we propose the use of ultrawide-band-gap semiconductors to trace changes in optical absorption from varying water compositions by measuring the photocurrent response at different wavelengths. Here, we use α-phase Ga<sub>2</sub>O<sub>3</sub> as a suitable material to measure a broad photocurrent response ranging from 200 to 465 nm. The photocurrent response consisted of three well-defined regions inherently linked to the rich electronic landscape of the material. Region (i) (200-250 nm) corresponds to band-to-band excitation of charge carriers, aligning well with the absorption characteristics of nitrates. Region (ii) (250-350 nm) corresponds to band tail-related transitions, allowing a photocurrent response to dissolved organic carbon concentrations. Finally, we utilize defect-mediated transitions in Region (iii) (350-465 nm) to monitor suspended solid concentrations. It was observed here that the sensitivity of the photocurrent response to the changing water composition strongly depends on the excitation wavelength, where 225, 260, and 465 nm excitation yielded (for our setup) the best results for the monitoring of nitrates, dissolved organic carbon, and suspended solid concentrations, respectively.

Authors

Institutions

Publication Details

Journal
ACS Applied Optical Materials
Published
2026-02-04
DOI
https://doi.org/10.1021/acsaom.5c00620
Primary Topic
Ga2O3 and related materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gallium Oxide-Based Photodetectors for Water Quality Monitoring

William J. Peveler, David G. Nicol, Núria Martínez-Carreras, Aurora Uras et al.
ACS Applied Optical Materials
Ga2O3 and related materials
article

Gallium Oxide-Based Photodetectors for Water Quality Monitoring

William J. Peveler, David G. Nicol, Núria Martínez-Carreras, Aurora Uras, Fabien C−P. Massabuau
article en

Abstract

We present an approach to water quality monitoring using gallium oxide (Ga<sub>2</sub>O<sub>3</sub>) ultrawide-band-gap semiconductors. Nitrates, dissolved organic carbon, and suspended solid concentrations are three commonly measured water quality parameters that display optical absorption ranging from the deep ultraviolet to the visible region. This broad spectral region poses a challenge for accurate and efficient (simultaneous) measurement of absorption/extinction arising from varying concentrations of these parameters because silicon (Si), the classical detector material, has poor performance across this optical region. To overcome these limitations, we propose the use of ultrawide-band-gap semiconductors to trace changes in optical absorption from varying water compositions by measuring the photocurrent response at different wavelengths. Here, we use α-phase Ga<sub>2</sub>O<sub>3</sub> as a suitable material to measure a broad photocurrent response ranging from 200 to 465 nm. The photocurrent response consisted of three well-defined regions inherently linked to the rich electronic landscape of the material. Region (i) (200-250 nm) corresponds to band-to-band excitation of charge carriers, aligning well with the absorption characteristics of nitrates. Region (ii) (250-350 nm) corresponds to band tail-related transitions, allowing a photocurrent response to dissolved organic carbon concentrations. Finally, we utilize defect-mediated transitions in Region (iii) (350-465 nm) to monitor suspended solid concentrations. It was observed here that the sensitivity of the photocurrent response to the changing water composition strongly depends on the excitation wavelength, where 225, 260, and 465 nm excitation yielded (for our setup) the best results for the monitoring of nitrates, dissolved organic carbon, and suspended solid concentrations, respectively.

ACS Applied Optical MaterialsVol. 4(2)
Centre National de la Recherche Scientifique (FR), Cato Institute (US), University of Strathclyde (GB), Luxembourg Institute of Science and Technology (LU), Laboratoire des Sciences des Procédés et des Matériaux (FR), Université Paris 1 Panthéon-Sorbonne (FR), University of Glasgow (GB)
Clean water and sanitation
Openalex Percentile: Top 67%
Ga2O3 and related materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.