Resilient Control Strategies for Urban Energy Transitions: A Robust HRES Sizing Typology for Nearly Zero Energy Ports

Ports located within dense urban environments face a major challenge in achieving deep decarbonization without compromising the reliability and safety of critical maritime operations. This study develops and validates a resilience-oriented control and sizing typology for Hybrid Renewable Energy Systems (HRESs), supporting the transition of a medium-sized Mediterranean port toward a Nearly Zero Energy Port (nZEP). The framework integrates five years of measured electrical demand at 15 min resolution to capture stochastic load variability, seasonal effects, and safety-critical peak events. Thirty-five HRES configurations are simulated using HOMER Pro, assessing photovoltaic and wind generation combined with alternative Energy Storage System (ESS) technologies under two grid-interface control strategies: Net Metering (NM) and non-NM curtailment-based operation. Conventional Lead–Acid batteries are compared with inherently safer Vanadium Redox Flow Batteries (VRFBs), while autonomy constraints of 24 h and 48 h are imposed to represent operational resilience. System performance is evaluated through a multi-criteria framework encompassing economic viability (Levelized Cost of Energy), environmental impact (Lifecycle Assessment-based carbon footprint), and operational reliability. Results indicate that NM-enabled HRES architectures significantly outperform non-NM configurations by exploiting the external grid as an active balancing layer. The optimal NM configuration achieves a Levelized Cost of Energy of 0.063 €/kWh under a 24 h autonomy constraint, while reducing operational carbon intensity to approximately 70 gCO2,eq/kWh, corresponding to a reduction exceeding 90% relative to baseline grid-dependent operation. In contrast, non-NM systems require substantial storage and generation oversizing to maintain resilience, resulting in higher curtailment losses and Levelized Cost of Energy values of 0.12–0.15 €/kWh. Across both control regimes, VRFB-based systems consistently exhibit superior robustness and safety performance compared to Lead–Acid alternatives. The proposed typology provides a transferable framework for resilient and low-carbon port microgrid design under real-world operational constraints.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-02-04
DOI
https://doi.org/10.3390/pr14030549
Primary Topic
Maritime Transport Emissions and Efficiency
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilient Control Strategies for Urban Energy Transitions: A Robust HRES Sizing Typology for Nearly Zero Energy Ports

Nikolaos Sifakis
Processes
Maritime Transport Emissions and Efficiency
article

Resilient Control Strategies for Urban Energy Transitions: A Robust HRES Sizing Typology for Nearly Zero Energy Ports

Nikolaos Sifakis
article en

Abstract

Ports located within dense urban environments face a major challenge in achieving deep decarbonization without compromising the reliability and safety of critical maritime operations. This study develops and validates a resilience-oriented control and sizing typology for Hybrid Renewable Energy Systems (HRESs), supporting the transition of a medium-sized Mediterranean port toward a Nearly Zero Energy Port (nZEP). The framework integrates five years of measured electrical demand at 15 min resolution to capture stochastic load variability, seasonal effects, and safety-critical peak events. Thirty-five HRES configurations are simulated using HOMER Pro, assessing photovoltaic and wind generation combined with alternative Energy Storage System (ESS) technologies under two grid-interface control strategies: Net Metering (NM) and non-NM curtailment-based operation. Conventional Lead–Acid batteries are compared with inherently safer Vanadium Redox Flow Batteries (VRFBs), while autonomy constraints of 24 h and 48 h are imposed to represent operational resilience. System performance is evaluated through a multi-criteria framework encompassing economic viability (Levelized Cost of Energy), environmental impact (Lifecycle Assessment-based carbon footprint), and operational reliability. Results indicate that NM-enabled HRES architectures significantly outperform non-NM configurations by exploiting the external grid as an active balancing layer. The optimal NM configuration achieves a Levelized Cost of Energy of 0.063 €/kWh under a 24 h autonomy constraint, while reducing operational carbon intensity to approximately 70 gCO2,eq/kWh, corresponding to a reduction exceeding 90% relative to baseline grid-dependent operation. In contrast, non-NM systems require substantial storage and generation oversizing to maintain resilience, resulting in higher curtailment losses and Levelized Cost of Energy values of 0.12–0.15 €/kWh. Across both control regimes, VRFB-based systems consistently exhibit superior robustness and safety performance compared to Lead–Acid alternatives. The proposed typology provides a transferable framework for resilient and low-carbon port microgrid design under real-world operational constraints.

ProcessesVol. 14(3)
Technical University of Crete (GR)
University of Crete
Openalex Percentile: Top 70%
Maritime Transport Emissions and Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.