Treatment of Circulating Water at Coke Plants by Catalytic Ozonolysis

Scientific principles for the ozonolytic treatment of circulating water at coke plants using zinc ferrite as the catalyst are developed. On adding 0.1 g of zinc ferrite to 50 mL of a phenol solution (concentration 1 g/L), the rate of destruction is doubled, with an ozone flux of 2.5 g/h. In the ozonolysis of circulating water, the initial colloidal structure of the sample breaks down. The characteristic destruction rate of phenolic compounds is found to be higher for circulating water than for an aqueous solution of phenol. The effective rate constant of phenol destruction in circulating water increases on adding zinc ferrite, but by a smaller amount than in an aqueous solution of phenol. That is associated with the need to oxidize the other organic compounds forming phenols in the initial stages. The proposed approach may be regarded as a promising means of reducing the energy consumption in ozonolysis and hence permitting the use of ozonolysis in decreasing the concentration of organic pollutants in the circulating water prior to biochemical treatment.

Authors

Institutions

Publication Details

Journal
Coke and Chemistry
Published
2025-10-01
DOI
https://doi.org/10.3103/s1068364x25601209
Primary Topic
Coal and Coke Industries Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment of Circulating Water at Coke Plants by Catalytic Ozonolysis

A. V. Kalensky, S. A. Yakovlev, A. B. Gordienko, A. A. Zvekov et al.
Coke and Chemistry
Coal and Coke Industries Research
article

Treatment of Circulating Water at Coke Plants by Catalytic Ozonolysis

A. V. Kalensky, S. A. Yakovlev, A. B. Gordienko, A. A. Zvekov, K. A. Korchuganova, A. V. Ivanov
article en

Abstract

Scientific principles for the ozonolytic treatment of circulating water at coke plants using zinc ferrite as the catalyst are developed. On adding 0.1 g of zinc ferrite to 50 mL of a phenol solution (concentration 1 g/L), the rate of destruction is doubled, with an ozone flux of 2.5 g/h. In the ozonolysis of circulating water, the initial colloidal structure of the sample breaks down. The characteristic destruction rate of phenolic compounds is found to be higher for circulating water than for an aqueous solution of phenol. The effective rate constant of phenol destruction in circulating water increases on adding zinc ferrite, but by a smaller amount than in an aqueous solution of phenol. That is associated with the need to oxidize the other organic compounds forming phenols in the initial stages. The proposed approach may be regarded as a promising means of reducing the energy consumption in ozonolysis and hence permitting the use of ozonolysis in decreasing the concentration of organic pollutants in the circulating water prior to biochemical treatment.

Coke and ChemistryVol. 68(10)
Kemerovo State University (RU)
Affordable and clean energy
Openalex Percentile: Top 22%
Coal and Coke Industries Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Treatment of Circulating Water at Coke Plants by Catalytic Ozonolysis — A. V. Kalensky, S. A. Yakovlev, et al. · Coke and Chemistry (2025) | TGRS Research Map | TGRS