Design and Verification of Electron Injection Unit for Small-Size Betatron

Betatrons offer advantages such as a compact structure and the absence of complex radio-frequency systems which make them well suited for industrial non-destructive testing and high-energy X-ray imaging. However, with the increasing miniaturization of betatrons, the design of the electron injection unit faces new technical challenges, and conventional electron injection schemes are no longer suitable for small-size betatrons. In this study, an electron injection unit is designed based on the operating characteristics of small-size betatrons. The proposed unit consists of a half-bridge filament drive circuit, a pulsed high-voltage circuit, and an injection current feedback circuit. The experimental results demonstrate that the optimal dose rate is achieved when the injection current is adjusted within a range of 0–1.2 A, with a nominal injection current of 0.8 A, fully satisfying the operational requirements of small-size betatrons. Compared with traditional electron injection schemes, the proposed design features a more compact circuit structure and provides an efficient and accurate solution for electron injection in electron accelerator systems.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-02-04
DOI
https://doi.org/10.3390/app16031562
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Verification of Electron Injection Unit for Small-Size Betatron

Rui Chen, Qi Liu, Yan Zhang, Haitao Wang et al.
Applied Sciences
Particle Accelerators and Free-Electron Lasers
article

Design and Verification of Electron Injection Unit for Small-Size Betatron

Rui Chen, Qi Liu, Yan Zhang, Haitao Wang, Shumin Zhou, Zejun Zhang
article en

Abstract

Betatrons offer advantages such as a compact structure and the absence of complex radio-frequency systems which make them well suited for industrial non-destructive testing and high-energy X-ray imaging. However, with the increasing miniaturization of betatrons, the design of the electron injection unit faces new technical challenges, and conventional electron injection schemes are no longer suitable for small-size betatrons. In this study, an electron injection unit is designed based on the operating characteristics of small-size betatrons. The proposed unit consists of a half-bridge filament drive circuit, a pulsed high-voltage circuit, and an injection current feedback circuit. The experimental results demonstrate that the optimal dose rate is achieved when the injection current is adjusted within a range of 0–1.2 A, with a nominal injection current of 0.8 A, fully satisfying the operational requirements of small-size betatrons. Compared with traditional electron injection schemes, the proposed design features a more compact circuit structure and provides an efficient and accurate solution for electron injection in electron accelerator systems.

Applied SciencesVol. 16(3)
East China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 66%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.