Vanadium removal from water assisted by FeCl3 using low pressure membranes

Abstract Vanadium (V), released from both natural and anthropogenic sources, occurs in groundwater and surface waters at 0.2–100 µg L −1 (freshwater) and 0.2–29 µg L −1 (seawater). This work evaluates V removal with low-pressure membranes (MV020 and UP150) enhanced with FeCl 3 . The effects of Fe/V molar ratio, transmembrane pressures (TMPs), and membrane type on removal efficiency and flux performance were examined. In a 60-min operational period, V rejection at Fe/V = 0 remained below 61.8% (UP150) and 24.5% (MV020). Raising the ratio at Fe/V = 1 increased removal to 73.9% (UP150) and 53.3% (MV020); at Fe/V = 3 the values rose to 88.3% and 60.2%, respectively. In 6-h operational period with UP150 at Fe/V = 3, peak removal reached 95.1%, but progressive fouling caused flux decline; after backwashing cycles the flux partially recovered while removal stabilised around 86%. SEM–EDS and FTIR analyses confirmed Fe–V interactions on membrane surfaces. Overall, FeCl 3 -assisted low-pressure UF offers high V rejection with moderate chemical demand, making it a compact and energy-efficient option for decentralised water treatment.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental Science and Technology
Published
2026-02-04
DOI
https://doi.org/10.1007/s13762-026-07084-6
Primary Topic
Environmental remediation with nanomaterials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vanadium removal from water assisted by FeCl3 using low pressure membranes

Fatih Acar, M. Cakmakci, O. K. Turk
International Journal of Environmental Science and Technology
Environmental remediation with nanomaterials
article

Vanadium removal from water assisted by FeCl3 using low pressure membranes

Fatih Acar, M. Cakmakci, O. K. Turk
article en

Abstract

Abstract Vanadium (V), released from both natural and anthropogenic sources, occurs in groundwater and surface waters at 0.2–100 µg L −1 (freshwater) and 0.2–29 µg L −1 (seawater). This work evaluates V removal with low-pressure membranes (MV020 and UP150) enhanced with FeCl 3 . The effects of Fe/V molar ratio, transmembrane pressures (TMPs), and membrane type on removal efficiency and flux performance were examined. In a 60-min operational period, V rejection at Fe/V = 0 remained below 61.8% (UP150) and 24.5% (MV020). Raising the ratio at Fe/V = 1 increased removal to 73.9% (UP150) and 53.3% (MV020); at Fe/V = 3 the values rose to 88.3% and 60.2%, respectively. In 6-h operational period with UP150 at Fe/V = 3, peak removal reached 95.1%, but progressive fouling caused flux decline; after backwashing cycles the flux partially recovered while removal stabilised around 86%. SEM–EDS and FTIR analyses confirmed Fe–V interactions on membrane surfaces. Overall, FeCl 3 -assisted low-pressure UF offers high V rejection with moderate chemical demand, making it a compact and energy-efficient option for decentralised water treatment.

International Journal of Environmental Science and TechnologyVol. 23(4)
Yıldız Technical University (TR)
Yildiz Teknik Üniversitesi
Clean water and sanitation, Life below water
Openalex Percentile: Top 67%
Environmental remediation with nanomaterials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.