Thermal Integrity Profiling of a Bored Pile in Limestone

ABSTRACT Recently developed Thermal Integrity Profiling (TIP), which measures the cast-in-place shaft concrete temperature, is a reliable method for integrity and quality testing used in foundation engineering. The local temperature variations during early-age concrete curing can identify various shaft anomalies. This article presents a field case study of thermal integrity testing of a 900 mm diameter bored pile placed in the Saudi Arabian Limestone formation. The results show that the effective average radius is consistent with the pile diameter up to the depths of around 7.50 m. A temperature drop was observed from 7.50 m to 8.0 m depth due to the presence of an anomaly in the form of a sacrificial jack assembly. A heat loss was identified at this location as a result of this assembly behaving as a heat sink. Moreover, the thermal data revealed that there is no cage eccentricity and no loss of any concrete cover in the tested shaft. This study provides indispensable information to Geotechnologists about the concrete integrity and quality of the shaft soon after the concreting for further decisionmaking.

Authors

Institutions

Publication Details

Journal
Journal of the Geological Society of India
Published
2026-02-01
DOI
https://doi.org/10.17491/jgsi/2026/174348
Primary Topic
Concrete Properties and Behavior
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Integrity Profiling of a Bored Pile in Limestone

Anil Cherian
Journal of the Geological Society of India
Concrete Properties and Behavior
article

Thermal Integrity Profiling of a Bored Pile in Limestone

Anil Cherian
article en

Abstract

ABSTRACT Recently developed Thermal Integrity Profiling (TIP), which measures the cast-in-place shaft concrete temperature, is a reliable method for integrity and quality testing used in foundation engineering. The local temperature variations during early-age concrete curing can identify various shaft anomalies. This article presents a field case study of thermal integrity testing of a 900 mm diameter bored pile placed in the Saudi Arabian Limestone formation. The results show that the effective average radius is consistent with the pile diameter up to the depths of around 7.50 m. A temperature drop was observed from 7.50 m to 8.0 m depth due to the presence of an anomaly in the form of a sacrificial jack assembly. A heat loss was identified at this location as a result of this assembly behaving as a heat sink. Moreover, the thermal data revealed that there is no cage eccentricity and no loss of any concrete cover in the tested shaft. This study provides indispensable information to Geotechnologists about the concrete integrity and quality of the shaft soon after the concreting for further decisionmaking.

Journal of the Geological Society of IndiaVol. 102(2)
Strainstall (United Kingdom) (GB)
Sustainable cities and communities
Openalex Percentile: Top 68%
Concrete Properties and Behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.