DTS: An Innovative Synchronization Method for Synchronous Condenser with the Electrical Grid

Abstract This paper presents an original deterministic approach to improve the success rate of the synchronization process of a synchronous condenser. In fact, the start-up process of a synchronous condenser cannot rely on the presence of a supply system to regulate its speed during the synchronization process, as happens with traditional synchronous generators. A static frequency converter is used to start the machine, but it should be disconnected before the grid synchronization to avoid damage, making the process uncontrollable. The proposed method aims to analytically determine the optimal frequency and phase angle to disconnect the converter to ensure synchronization with the grid within proper thresholds. The accuracy of the method is confirmed by a comparison with on-field recording of real synchronous condenser start-up processes. This procedure enables significantly reducing the frequency threshold for the synchronization so to limit the thermal and mechanical stresses of the machine and to increase its lifecycle.

Authors

Institutions

Publication Details

Journal
B&H eletrical engineering
Published
2026-02-04
DOI
https://doi.org/10.2478/bhee-2026-0020
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DTS: An Innovative Synchronization Method for Synchronous Condenser with the Electrical Grid

Roberto Benato, Domenico Tedeschi, Francesco Sanniti, Luca Rusalen
B&H eletrical engineering
Microgrid Control and Optimization
article

DTS: An Innovative Synchronization Method for Synchronous Condenser with the Electrical Grid

Roberto Benato, Domenico Tedeschi, Francesco Sanniti, Luca Rusalen
article en

Abstract

Abstract This paper presents an original deterministic approach to improve the success rate of the synchronization process of a synchronous condenser. In fact, the start-up process of a synchronous condenser cannot rely on the presence of a supply system to regulate its speed during the synchronization process, as happens with traditional synchronous generators. A static frequency converter is used to start the machine, but it should be disconnected before the grid synchronization to avoid damage, making the process uncontrollable. The proposed method aims to analytically determine the optimal frequency and phase angle to disconnect the converter to ensure synchronization with the grid within proper thresholds. The accuracy of the method is confirmed by a comparison with on-field recording of real synchronous condenser start-up processes. This procedure enables significantly reducing the frequency threshold for the synchronization so to limit the thermal and mechanical stresses of the machine and to increase its lifecycle.

B&H eletrical engineering
University of Padua (IT), Terna (Italy) (IT)
Openalex Percentile: Top 67%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DTS: An Innovative Synchronization Method for Synchronous Condenser with the Electrical Grid — Roberto Benato, Domenico Tedeschi, et al. · B&H eletrical engineering (2026) | TGRS Research Map | TGRS