Minimizing energy consumption and providing improved thermal comfort for buildings by incorporating false ceiling and mechanical ventilation

Buildings use a substantial portion of energy for air conditioning and heating purposes. Implementing energy-efficient retrofits in buildings is an essential procedure for decreasing emissions and mitigating the impacts of climate change. In this study, a combination of false ceiling and mechanical ventilation system is introduced as an energy-efficient retrofit to decrease energy usage and increase thermal comfort in buildings. Installing a false ceiling beneath the roof creates a thermal barrier, reducing heat transfer into the building. Additionally, incorporating mechanical ventilation in the space between the roof and the false ceiling helps remove trapped hot air, thereby keeping the top floor cooler. This study numerically examines the impact of applying false ceilings and mechanical ventilation on room temperature and total energy consumption using DesignBuilder software. The proposed investigation was initially conducted on a typical model building, and the findings were then applied to a real building through numerical simulation to evaluate their practical effectiveness. Installing a false ceiling under the roof, with gaps ranging from 0.2 m to 0.4 m, can lower room temperature by up to 1.39 °C and reduce overall energy use by up to 11.59%. Introducing mechanical ventilation between the roof and false ceiling further enhances performance, achieving temperature reductions of up to 2.21 °C and additional energy savings of 5.9% to 7.3%. When applied to a real building, a 0.3 m ceiling gap combined with ventilation rates of 3.0–4.5 ACH reduced energy consumption by up to 15.43%. Overall, the combined strategy significantly improves thermal comfort and energy efficiency.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-04
DOI
https://doi.org/10.1038/s41598-026-36888-2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimizing energy consumption and providing improved thermal comfort for buildings by incorporating false ceiling and mechanical ventilation

Mohammad Rezwan Hossain, Khaza Shahriar, Md. Hasan Ali, Md. Mahmodul Alam
Scientific Reports
Building Energy and Comfort Optimization
article

Minimizing energy consumption and providing improved thermal comfort for buildings by incorporating false ceiling and mechanical ventilation

Mohammad Rezwan Hossain, Khaza Shahriar, Md. Hasan Ali, Md. Mahmodul Alam
article en

Abstract

Buildings use a substantial portion of energy for air conditioning and heating purposes. Implementing energy-efficient retrofits in buildings is an essential procedure for decreasing emissions and mitigating the impacts of climate change. In this study, a combination of false ceiling and mechanical ventilation system is introduced as an energy-efficient retrofit to decrease energy usage and increase thermal comfort in buildings. Installing a false ceiling beneath the roof creates a thermal barrier, reducing heat transfer into the building. Additionally, incorporating mechanical ventilation in the space between the roof and the false ceiling helps remove trapped hot air, thereby keeping the top floor cooler. This study numerically examines the impact of applying false ceilings and mechanical ventilation on room temperature and total energy consumption using DesignBuilder software. The proposed investigation was initially conducted on a typical model building, and the findings were then applied to a real building through numerical simulation to evaluate their practical effectiveness. Installing a false ceiling under the roof, with gaps ranging from 0.2 m to 0.4 m, can lower room temperature by up to 1.39 °C and reduce overall energy use by up to 11.59%. Introducing mechanical ventilation between the roof and false ceiling further enhances performance, achieving temperature reductions of up to 2.21 °C and additional energy savings of 5.9% to 7.3%. When applied to a real building, a 0.3 m ceiling gap combined with ventilation rates of 3.0–4.5 ACH reduced energy consumption by up to 15.43%. Overall, the combined strategy significantly improves thermal comfort and energy efficiency.

Scientific ReportsVol. 16(1)
Khulna University of Engineering and Technology (BD)
Khulna University
Affordable and clean energy
Openalex Percentile: Top 66%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Minimizing energy consumption and providing improved thermal comfort for buildings by incorporating false ceiling and mechanical ventilation — Mohammad Rezwan Hossain, Khaza Shahriar, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS