An Amplitude−Time Scintillation Spectrometer

A two-channel scintillation spectrometer with a thickness of 0.5X0 has been calibrated on the secondary electron beam at the Pakhra accelerator of the Lebedev Physical Institute, Russian Academy of Sciences. The amplitude and time recording systems of the spectrometer are based on FEU-49 and FEU-85 photomultiplier tubes, respectively. The relative energy resolution of the scintillation spectrometer is ~5% at electron energy E ∼ 30 MeV. The nonlinear dependence of the average channel of the time-resolved spectrum on the electron energy is observed at electron energies E < 40 MeV, and the average channel of the time-resolved spectrum is independent of the energy at E ≥ 40 MeV.

Authors

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2025-10-01
DOI
https://doi.org/10.1134/s0020441225701015
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Amplitude−Time Scintillation Spectrometer

Yu. F. Krechetov, V. A. Dronov, A. V. Kolzov, V. I. Alekseev et al.
Instruments and Experimental Techniques
Radioactive Decay and Measurement Techniques
article

An Amplitude−Time Scintillation Spectrometer

Yu. F. Krechetov, V. A. Dronov, A. V. Kolzov, V. I. Alekseev, E. A. Khafizova, S. M. Akhmad, V. A. Baskov, A. I. L’vov, S. S. Sidorin, V. V. Poliansky
article en

Abstract

A two-channel scintillation spectrometer with a thickness of 0.5X0 has been calibrated on the secondary electron beam at the Pakhra accelerator of the Lebedev Physical Institute, Russian Academy of Sciences. The amplitude and time recording systems of the spectrometer are based on FEU-49 and FEU-85 photomultiplier tubes, respectively. The relative energy resolution of the scintillation spectrometer is ~5% at electron energy E ∼ 30 MeV. The nonlinear dependence of the average channel of the time-resolved spectrum on the electron energy is observed at electron energies E < 40 MeV, and the average channel of the time-resolved spectrum is independent of the energy at E ≥ 40 MeV.

Instruments and Experimental TechniquesVol. 68(5)
P.N. Lebedev Physical Institute of the Russian Academy of Sciences (RU), Moscow State Pedagogical University (RU), Joint Institute for Nuclear Research (RU)
Affordable and clean energy
Openalex Percentile: Top 24%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.