Wearable Biomechanics and Video-Based Trajectory Analysis for Improving Performance in Alpine Skiing

Performance diagnostics in alpine skiing increasingly rely on integrated biomechanical and kinematic assessments to support technique optimization under real training conditions; however, many existing approaches address trajectory geometry or biomechanical variables separately, limiting their explanatory power. This study evaluates an integrated analysis framework combining OptiPath, an AI-assisted video-based trajectory analysis tool, with XSensDOT wearable inertial sensors to identify technical inefficiencies during giant slalom skiing. Thirty competitive youth athletes (<i>n</i> = 30; 14-16 years) performed controlled runs with predefined lateral offsets from the gates, enabling systematic examination of the relationship between spatial trajectory deviations, biomechanical execution, and performance outcomes. Skier trajectories were extracted using computer vision-based methods, while lower-limb kinematics, trunk motion, and tri-axial acceleration were recorded using inertial measurement units. Deviations from mathematically defined ideal trajectories were quantified through regression-based calibration and arc-based modeling. The results show that although OptiPath reliably detected trajectory variations, shorter skiing paths did not consistently produce faster run times. Instead, superior performance was associated with more efficient biomechanical execution, reflected by coordinated trunk-lower limb motion, controlled vertical loading, reduced lateral corrections, and higher forward acceleration, even when longer trajectories were followed. These findings indicate that trajectory geometry alone is insufficient to explain performance outcomes and support the integration of wearable biomechanics with trajectory modeling as a practical, low-cost, and field-deployable tool for alpine skiing performance diagnostics.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-04
DOI
https://doi.org/10.3390/s26031010
Primary Topic
Winter Sports Injuries and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Biomechanics and Video-Based Trajectory Analysis for Improving Performance in Alpine Skiing

Dorin Cătană, Denisa-Iulia Brus
Sensors
Winter Sports Injuries and Performance
article

Wearable Biomechanics and Video-Based Trajectory Analysis for Improving Performance in Alpine Skiing

Dorin Cătană, Denisa-Iulia Brus
article en

Abstract

Performance diagnostics in alpine skiing increasingly rely on integrated biomechanical and kinematic assessments to support technique optimization under real training conditions; however, many existing approaches address trajectory geometry or biomechanical variables separately, limiting their explanatory power. This study evaluates an integrated analysis framework combining OptiPath, an AI-assisted video-based trajectory analysis tool, with XSensDOT wearable inertial sensors to identify technical inefficiencies during giant slalom skiing. Thirty competitive youth athletes (<i>n</i> = 30; 14-16 years) performed controlled runs with predefined lateral offsets from the gates, enabling systematic examination of the relationship between spatial trajectory deviations, biomechanical execution, and performance outcomes. Skier trajectories were extracted using computer vision-based methods, while lower-limb kinematics, trunk motion, and tri-axial acceleration were recorded using inertial measurement units. Deviations from mathematically defined ideal trajectories were quantified through regression-based calibration and arc-based modeling. The results show that although OptiPath reliably detected trajectory variations, shorter skiing paths did not consistently produce faster run times. Instead, superior performance was associated with more efficient biomechanical execution, reflected by coordinated trunk-lower limb motion, controlled vertical loading, reduced lateral corrections, and higher forward acceleration, even when longer trajectories were followed. These findings indicate that trajectory geometry alone is insufficient to explain performance outcomes and support the integration of wearable biomechanics with trajectory modeling as a practical, low-cost, and field-deployable tool for alpine skiing performance diagnostics.

SensorsVol. 26(3)
Transylvania University of Brașov (RO)
Openalex Percentile: Top 68%
Winter Sports Injuries and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.