PID Regulation Enabling Multi-Bifurcation Instability of a Hydroelectric Power Generation System in the Infinite-Bus Power System

The integration of new energy into the grid has significantly intensified power grid operational pressure, posing higher demands on hydropower system regulation. As a key unit for power grid load tracking and stability maintenance, parameter mismatch of the PID governor is prone to inducing system bifurcation, thus leading to oscillatory instability, which has emerged as a critical challenge affecting the reliable consumption and sustainable supply of new energy. To address this challenge, a hydroelectric power generation system (HPGS) model in the infinite-bus power system is established. Bifurcation analysis is employed to quantitatively identify the critical thresholds of PID parameters that cause HPGS instability. Based on this, system dynamic response processes under critical thresholds are clarified using time-domain analysis. Furthermore, the potential oscillation instability mechanism is revealed using eigenvalue analysis, and suggestions for PID parameter selection are provided. Key quantitative results indicate that variations in proportional gain, kp, induce five limit point bifurcations. The system enters an unstable region when kp exceeds 2.467, whereas operation within the range below 0.891 is conducive to system stability. A supercritical Hopf bifurcation arises when integral gain ki reaches 0.925, so strict restrictions should be imposed on ki to avoid operating around this critical value. Two supercritical Hopf bifurcations that may trigger system oscillatory instability are identified during differential gain kd changing, and it should be regulated to a level below 5.188 to ensure system stability. By integrating bifurcation analysis, time-domain analysis, and eigenvalue analysis, this study effectively improves the accuracy of characterizing system dynamic behaviors, providing a clear quantitative basis for PID parameter optimization and bifurcation suppression, as well as laying a theoretical foundation for hydropower system stable operation and the efficient absorption of new energy.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-02-04
DOI
https://doi.org/10.3390/su18031585
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PID Regulation Enabling Multi-Bifurcation Instability of a Hydroelectric Power Generation System in the Infinite-Bus Power System

Lihong Zhang, Di Liu, Jingjing Zhang, Md. Apel Mahmud et al.
Sustainability
Power System Optimization and Stability
article

PID Regulation Enabling Multi-Bifurcation Instability of a Hydroelectric Power Generation System in the Infinite-Bus Power System

Lihong Zhang, Di Liu, Jingjing Zhang, Md. Apel Mahmud, Huhang Ding
article en

Abstract

The integration of new energy into the grid has significantly intensified power grid operational pressure, posing higher demands on hydropower system regulation. As a key unit for power grid load tracking and stability maintenance, parameter mismatch of the PID governor is prone to inducing system bifurcation, thus leading to oscillatory instability, which has emerged as a critical challenge affecting the reliable consumption and sustainable supply of new energy. To address this challenge, a hydroelectric power generation system (HPGS) model in the infinite-bus power system is established. Bifurcation analysis is employed to quantitatively identify the critical thresholds of PID parameters that cause HPGS instability. Based on this, system dynamic response processes under critical thresholds are clarified using time-domain analysis. Furthermore, the potential oscillation instability mechanism is revealed using eigenvalue analysis, and suggestions for PID parameter selection are provided. Key quantitative results indicate that variations in proportional gain, kp, induce five limit point bifurcations. The system enters an unstable region when kp exceeds 2.467, whereas operation within the range below 0.891 is conducive to system stability. A supercritical Hopf bifurcation arises when integral gain ki reaches 0.925, so strict restrictions should be imposed on ki to avoid operating around this critical value. Two supercritical Hopf bifurcations that may trigger system oscillatory instability are identified during differential gain kd changing, and it should be regulated to a level below 5.188 to ensure system stability. By integrating bifurcation analysis, time-domain analysis, and eigenvalue analysis, this study effectively improves the accuracy of characterizing system dynamic behaviors, providing a clear quantitative basis for PID parameter optimization and bifurcation suppression, as well as laying a theoretical foundation for hydropower system stable operation and the efficient absorption of new energy.

SustainabilityVol. 18(3)
Flinders University (AU), North China University of Water Resources and Electric Power (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 67%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.