Dependence of UHF Partial Discharge Detection and Source Positioning in Power Transformers on Different Input Pulse Frequency Ranges

Abstract Transformer insulation is gradually weakened by partial discharges (PDs), which might eventually result in complete transformer failure if left unchecked. Different types of sources can produce PD signals, which can be detected throughout a wide frequency range. Preventive maintenance of power transformers depends on the characteristics of received ultra-high frequency (UHF) PD signals at sensors and the positioning of their source. This study compares and analyses the effects of different input pulse frequency ranges (IPFRs), the transformer tank, the active components of the transformer, dispositions of UHF sensors relative to PD source, the total efficiency of the used antenna and superimposed reflected waves on received signals’ waveforms, times of arrivals (TOAs) and magnitudes of their first peaks (FPs), time differences of appearances and magnitude ratios between the extreme amplitudes and FPs in their first wave packets, as well as variations in their amplitude spectra.

Authors

Institutions

Publication Details

Journal
B&H eletrical engineering
Published
2026-02-04
DOI
https://doi.org/10.2478/bhee-2026-0019
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dependence of UHF Partial Discharge Detection and Source Positioning in Power Transformers on Different Input Pulse Frequency Ranges

Đorđe Dukanac
B&H eletrical engineering
High voltage insulation and dielectric phenomena
article

Dependence of UHF Partial Discharge Detection and Source Positioning in Power Transformers on Different Input Pulse Frequency Ranges

Đorđe Dukanac
article en

Abstract

Abstract Transformer insulation is gradually weakened by partial discharges (PDs), which might eventually result in complete transformer failure if left unchecked. Different types of sources can produce PD signals, which can be detected throughout a wide frequency range. Preventive maintenance of power transformers depends on the characteristics of received ultra-high frequency (UHF) PD signals at sensors and the positioning of their source. This study compares and analyses the effects of different input pulse frequency ranges (IPFRs), the transformer tank, the active components of the transformer, dispositions of UHF sensors relative to PD source, the total efficiency of the used antenna and superimposed reflected waves on received signals’ waveforms, times of arrivals (TOAs) and magnitudes of their first peaks (FPs), time differences of appearances and magnitude ratios between the extreme amplitudes and FPs in their first wave packets, as well as variations in their amplitude spectra.

B&H eletrical engineering
Telekom Srbija (Serbia) (RS)
Affordable and clean energy
Openalex Percentile: Top 68%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.