Optimizing platelet transfusions: A comparative analysis of corrected count increment in platelet aphaeresis with and without platelet additive solution

Abstract: BACKGROUND: Platelet transfusions are essential in managing thrombocytopenia, commonly seen in patients undergoing chemotherapy, bone marrow transplants, and other hematologic disorders. This study focuses specifically on aphaeresis platelet transfusions. A platelet additive solution (PAS) has been proposed to enhance the quality and safety of these transfusions. This study compares the efficacy and safety of aphaeresis platelet transfusions prepared with PAS versus without PAS (Plasma). MATERIALS AND METHODS: A retrospective observational study was conducted at a tertiary care hospital in Northwestern India between January 2019 and December 2021. The study included 200 patients who received platelet transfusions. Corrected count increment (CCI) was calculated from pre and posttransfusion platelet counts measured consistently 24 h after the transfusion to ensure accuracy. Adverse reactions were monitored and documented. Statistical analyses included independent samples t -tests and additional tests for categorical variables. RESULTS: The study comprised 200 patients (PAS group: 100; non-PAS group: 100). The mean CCI was significantly higher in the PAS group (mean ± standard deviation: 15,500 ± 3500) compared to the non-PAS group (12,000 ± 4000) ( P < 0.00001). Fewer allergic reactions were observed in the PAS group (3 cases) than in the non-PAS (Plasma) group (10 cases). Patient age and weight had minimal influence on CCI. Weak correlations were observed between CCI and age (with PAS: −0.072, without PAS: −0.142) and between CCI and weight (with PAS: 0.052, without PAS: 0.239). CONCLUSION: Platelet transfusions prepared with PAS are significantly more effective, as indicated by a higher CCI, and safer, with fewer allergic reactions, compared to those prepared without PAS. The findings support the use of PAS in clinical practice to improve the outcomes of platelet transfusions. Future research should explore the long-term benefits and underlying mechanisms of PAS to further optimize transfusion practices.

Authors

Institutions

Publication Details

Journal
Asian Journal of Transfusion Science
Published
2026-02-04
DOI
https://doi.org/10.4103/ajts.ajts_127_24
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing platelet transfusions: A comparative analysis of corrected count increment in platelet aphaeresis with and without platelet additive solution

Anshika Yadav, Pankaj Kumar Agarwal, Gajendra Nath Gupta, Garima Agarwal
Asian Journal of Transfusion Science
Blood transfusion and management
article

Optimizing platelet transfusions: A comparative analysis of corrected count increment in platelet aphaeresis with and without platelet additive solution

Anshika Yadav, Pankaj Kumar Agarwal, Gajendra Nath Gupta, Garima Agarwal
article en

Abstract

Abstract: BACKGROUND: Platelet transfusions are essential in managing thrombocytopenia, commonly seen in patients undergoing chemotherapy, bone marrow transplants, and other hematologic disorders. This study focuses specifically on aphaeresis platelet transfusions. A platelet additive solution (PAS) has been proposed to enhance the quality and safety of these transfusions. This study compares the efficacy and safety of aphaeresis platelet transfusions prepared with PAS versus without PAS (Plasma). MATERIALS AND METHODS: A retrospective observational study was conducted at a tertiary care hospital in Northwestern India between January 2019 and December 2021. The study included 200 patients who received platelet transfusions. Corrected count increment (CCI) was calculated from pre and posttransfusion platelet counts measured consistently 24 h after the transfusion to ensure accuracy. Adverse reactions were monitored and documented. Statistical analyses included independent samples t -tests and additional tests for categorical variables. RESULTS: The study comprised 200 patients (PAS group: 100; non-PAS group: 100). The mean CCI was significantly higher in the PAS group (mean ± standard deviation: 15,500 ± 3500) compared to the non-PAS group (12,000 ± 4000) ( P < 0.00001). Fewer allergic reactions were observed in the PAS group (3 cases) than in the non-PAS (Plasma) group (10 cases). Patient age and weight had minimal influence on CCI. Weak correlations were observed between CCI and age (with PAS: −0.072, without PAS: −0.142) and between CCI and weight (with PAS: 0.052, without PAS: 0.239). CONCLUSION: Platelet transfusions prepared with PAS are significantly more effective, as indicated by a higher CCI, and safer, with fewer allergic reactions, compared to those prepared without PAS. The findings support the use of PAS in clinical practice to improve the outcomes of platelet transfusions. Future research should explore the long-term benefits and underlying mechanisms of PAS to further optimize transfusion practices.

Asian Journal of Transfusion Science
Santokba Durlabhji Memorial hospital (IN)
Openalex Percentile: Top 68%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.