Quality-by-Design Compounding of Semisolids Using an Electronic Mortar and Pestle Device for Compounding Pharmacies: Uniformity, Stability, and Cleaning

<b>Background/Objectives</b>: Manual preparation of semisolid formulations (creams, ointments, gels) is prone to variability in mixing energy and time, which may compromise uniform API distribution. This study aimed to evaluate an Electronic Mortar and Pestle (EMP; Unguator™) as a standardized compounding tool, with objectives to: (i) validate stability-indicating UHPLC methods; (ii) assess content uniformity across jar strata; (iii) quantify the impact of mixing time and rotation speed via design of experiments (DOE); and (iv) verify cleaning effectiveness and cross-contamination risk. <b>Methods</b>: Five representative formulations were compounded: urea 40%, clobetasol 0.05%, diclofenac 2.5% in hyaluronic acid 3% gel, urea 10% + salicylic acid 1%, and hydroquinone 5%. UHPLC methods were validated per ICH Q2(R2) and stress-tested under acid, base, oxidative, thermal, and UV conditions. Homogeneity was assessed by stratified sampling (top/middle/bottom). A 3<sup>2</sup> factorial DOE (time: 2/6/10 min; speed: 600/1500/2400 rpm) modeled effects on % label claim and RSD. Cleaning validation employed hydroquinone as a tracer, with swab sampling pre-/post-use and post-sanitization analyzed by HPLC. <b>Results</b>: All UHPLC methods met specificity, linearity, precision, accuracy, and sensitivity criteria and were stability-indicating (Rs ≥ 1.5). Formulations achieved 90-110% label claim with strata CV ≤ 5%. DOE revealed speed as the dominant factor for clobetasol, urea, and diclofenac, while time was more influential for salicylic acid; gels exhibited curvature, indicating diminishing returns at high rpm. Model-predicted optima were implementable on the Unguator™ with minor rounding of rpm/time. Cleaning validation confirmed post-sanitization residues below LOQ and <10 ppm acceptance. <b>Conclusions</b>: The Unguator™ provides a practical, parameter-controlled route for compounding pharmacies to standardize semisolid preparations, achieving reproducible layer-to-layer content uniformity within predefined criteria under the evaluated conditions through programmable set-points and validated cycles. DOE-derived rpm-time relationships define an operational design space within the studied ranges and support selection of implementable device settings and set-points. Importantly, the DOE-derived "optima" in this study are optimized for assay-based content uniformity (mean % label claim and strata variability). Cleaning validation supports a closed, low-cross-contamination workflow, facilitating consistent routines for both routine and complex formulations. Overall, the work implements selected QbD elements (QTPP-Quality Target Product Profile; CQA-Critical Quality Attribute definition; CPP-Critical Process Parameter identification; operational design space; and a proposed control strategy) and should be viewed as a step toward broader lifecycle QbD implementation in compounding.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2026-02-04
DOI
https://doi.org/10.3390/pharmaceutics18020205
Primary Topic
Safe Handling of Antineoplastic Drugs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality-by-Design Compounding of Semisolids Using an Electronic Mortar and Pestle Device for Compounding Pharmacies: Uniformity, Stability, and Cleaning

Carolina Schettino Kegele, Savvas Koulouridas, Hudson Polonini, Marcone Augusto Leal de Oliveira
Pharmaceutics
Safe Handling of Antineoplastic Drugs
article

Quality-by-Design Compounding of Semisolids Using an Electronic Mortar and Pestle Device for Compounding Pharmacies: Uniformity, Stability, and Cleaning

Carolina Schettino Kegele, Savvas Koulouridas, Hudson Polonini, Marcone Augusto Leal de Oliveira
article en

Abstract

<b>Background/Objectives</b>: Manual preparation of semisolid formulations (creams, ointments, gels) is prone to variability in mixing energy and time, which may compromise uniform API distribution. This study aimed to evaluate an Electronic Mortar and Pestle (EMP; Unguator™) as a standardized compounding tool, with objectives to: (i) validate stability-indicating UHPLC methods; (ii) assess content uniformity across jar strata; (iii) quantify the impact of mixing time and rotation speed via design of experiments (DOE); and (iv) verify cleaning effectiveness and cross-contamination risk. <b>Methods</b>: Five representative formulations were compounded: urea 40%, clobetasol 0.05%, diclofenac 2.5% in hyaluronic acid 3% gel, urea 10% + salicylic acid 1%, and hydroquinone 5%. UHPLC methods were validated per ICH Q2(R2) and stress-tested under acid, base, oxidative, thermal, and UV conditions. Homogeneity was assessed by stratified sampling (top/middle/bottom). A 3<sup>2</sup> factorial DOE (time: 2/6/10 min; speed: 600/1500/2400 rpm) modeled effects on % label claim and RSD. Cleaning validation employed hydroquinone as a tracer, with swab sampling pre-/post-use and post-sanitization analyzed by HPLC. <b>Results</b>: All UHPLC methods met specificity, linearity, precision, accuracy, and sensitivity criteria and were stability-indicating (Rs ≥ 1.5). Formulations achieved 90-110% label claim with strata CV ≤ 5%. DOE revealed speed as the dominant factor for clobetasol, urea, and diclofenac, while time was more influential for salicylic acid; gels exhibited curvature, indicating diminishing returns at high rpm. Model-predicted optima were implementable on the Unguator™ with minor rounding of rpm/time. Cleaning validation confirmed post-sanitization residues below LOQ and <10 ppm acceptance. <b>Conclusions</b>: The Unguator™ provides a practical, parameter-controlled route for compounding pharmacies to standardize semisolid preparations, achieving reproducible layer-to-layer content uniformity within predefined criteria under the evaluated conditions through programmable set-points and validated cycles. DOE-derived rpm-time relationships define an operational design space within the studied ranges and support selection of implementable device settings and set-points. Importantly, the DOE-derived "optima" in this study are optimized for assay-based content uniformity (mean % label claim and strata variability). Cleaning validation supports a closed, low-cross-contamination workflow, facilitating consistent routines for both routine and complex formulations. Overall, the work implements selected QbD elements (QTPP-Quality Target Product Profile; CQA-Critical Quality Attribute definition; CPP-Critical Process Parameter identification; operational design space; and a proposed control strategy) and should be viewed as a step toward broader lifecycle QbD implementation in compounding.

PharmaceuticsVol. 18(2)
Universidade Federal de Juiz de Fora (BR), International Council for Research and Innovation in Building and Construction (NL)
Openalex Percentile: Top 66%
Safe Handling of Antineoplastic Drugs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.