A Historical Evaluation of Articular Cartilage Lubrication Studies Reveals Distinct Testing Approach Specific Behaviors

Abstract Healthy articular cartilage can sustain near-frictionless motion within the joint; in vivo friction coefficients fall well within the superlubricity regime (<0.01). However, despite nearly a century of study, the mechanisms underpinning these behaviors remain unclear. This uncertainty has been compounded by how cartilage's operating conditions have been defined and subsequently extended to explant testing approaches, resulting in drastically varied tribological responses. To address these discrepancies, we compared friction coefficient results from a comprehensive set of historical cartilage explant tribology studies, and from new data evaluating testing configuration (stationary contact area (SCA) versus convergent SCA (cSCA)) and lubricant (phosphate-buffered saline versus synovial fluid (SF)) choice on friction. These data demonstrate that the SCA, the most common testing configuration utilized, consistently reports friction greater than that of the migrating contact area (MCA) and cSCA configurations. Intriguingly, while the SCA and MCA are almost universally slid at sub-physiological speeds (∼1 mm/s), the cSCA has routinely been tested at more physiologically consistent speeds (∼60 mm/s). Nevertheless, SF drives noticeable reductions in friction within both SCA and cSCA studies. Importantly, particularly in vivo, only rapidly slid, SF-lubricated cSCA cartilage explants reliably demonstrate biofidelic friction (<0.005), indicating that hydrodynamic-related phenomena must not be discounted in cartilage lubrication. Collectively, these results underscore the need to further probe mechanisms of sustained cartilage superlubricity, a key finding only recently replicated via the cSCA configuration. Such knowledge will be crucial to understanding the true lubrication capacity of articular cartilage.

Authors

Institutions

Publication Details

Journal
Journal of Tribology
Published
2026-02-04
DOI
https://doi.org/10.1115/1.4071015
Primary Topic
Osteoarthritis Treatment and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Historical Evaluation of Articular Cartilage Lubrication Studies Reveals Distinct Testing Approach Specific Behaviors

David L. Burris, Emily P. Lambeth, Christopher Price, Meghan E. Kupratis
Journal of Tribology
Osteoarthritis Treatment and Mechanisms
article

A Historical Evaluation of Articular Cartilage Lubrication Studies Reveals Distinct Testing Approach Specific Behaviors

David L. Burris, Emily P. Lambeth, Christopher Price, Meghan E. Kupratis
article en

Abstract

Abstract Healthy articular cartilage can sustain near-frictionless motion within the joint; in vivo friction coefficients fall well within the superlubricity regime (<0.01). However, despite nearly a century of study, the mechanisms underpinning these behaviors remain unclear. This uncertainty has been compounded by how cartilage's operating conditions have been defined and subsequently extended to explant testing approaches, resulting in drastically varied tribological responses. To address these discrepancies, we compared friction coefficient results from a comprehensive set of historical cartilage explant tribology studies, and from new data evaluating testing configuration (stationary contact area (SCA) versus convergent SCA (cSCA)) and lubricant (phosphate-buffered saline versus synovial fluid (SF)) choice on friction. These data demonstrate that the SCA, the most common testing configuration utilized, consistently reports friction greater than that of the migrating contact area (MCA) and cSCA configurations. Intriguingly, while the SCA and MCA are almost universally slid at sub-physiological speeds (∼1 mm/s), the cSCA has routinely been tested at more physiologically consistent speeds (∼60 mm/s). Nevertheless, SF drives noticeable reductions in friction within both SCA and cSCA studies. Importantly, particularly in vivo, only rapidly slid, SF-lubricated cSCA cartilage explants reliably demonstrate biofidelic friction (<0.005), indicating that hydrodynamic-related phenomena must not be discounted in cartilage lubrication. Collectively, these results underscore the need to further probe mechanisms of sustained cartilage superlubricity, a key finding only recently replicated via the cSCA configuration. Such knowledge will be crucial to understanding the true lubrication capacity of articular cartilage.

Journal of TribologyVol. 148(5)
Delaware Academy of Medicine (US), University of Delaware (US)
Openalex Percentile: Top 68%
Osteoarthritis Treatment and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.