Deception Detection from Five-Channel Wearable EEG on LieWaves: A Reproducible Baseline for Subject-Dependent and Subject-Independent Evaluation

Deception detection with low-channel wearable EEG requires protocols that generalize across people while remaining practical for portable devices. Using the public LieWaves dataset (27 subjects recorded with a five-channel Emotiv Insight headset), we evaluate to what extent five-channel head-mounted EEG can support lie-truth discrimination under both subject-independent and subject-dependent evaluations. For the subject-independent setting, we train a compact Residual Network with Squeeze-and-Excitation blocks (ResNet-SE) model on raw overlapping windows with focal loss, light data augmentation, and grouped cross-validation by subject; out-of-fold window probabilities are averaged per session and converted to labels using a single decision threshold estimated from the cross-validated session scores. For the subject-dependent setting, we adopt an overlapping short-window Residual Temporal Convolutional Network with Squeeze-and-Excitation and Attention (Res-TCN-SE-Attention) model that fuses raw EEG with discrete wavelet transform (DWT)-based spectral and handcrafted band-power and Hjorth features, using an 80/10/10 split at the recording/session level (stratified by session label), so that all windows from a given session are assigned to a single subset; because each subject contributes two sessions, the same subject may still appear across subsets via different sessions. The subject-independent model attains 66.70% session-level accuracy with an AUC of 0.58 on unseen subjects, underscoring the difficulty of person-independent generalization from low-channel wearable EEG. Because practical deployment requires generalization to previously unseen individuals, we treat the subject-independent evaluation as the primary estimate of real-world generalization. In contrast, the subject-dependent pipeline reaches 99.94% window-level accuracy under the overlapping sliding-window (OSW) setting with a session-disjoint split (no session contributes windows to more than one subset). This near-ceiling performance reflects the optimistic nature of subject-dependent evaluation with highly overlapping windows, even when avoiding within-session train-test overlap, and should not be interpreted as a meaningful indicator of deception-detection capability under realistic deployment constraints. These results suggest limited, above-chance separability between lie and truth sessions in LieWaves using a five-channel wearable EEG under the studied protocol; however, performance remains far from deployment-ready and is strongly shaped by evaluation design. Explicit reporting of both protocols, together with clear rules for windowing, aggregation, and threshold selection, supports more reproducible and comparable benchmarking.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-04
DOI
https://doi.org/10.3390/s26031027
Primary Topic
Deception detection and forensic psychology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deception Detection from Five-Channel Wearable EEG on LieWaves: A Reproducible Baseline for Subject-Dependent and Subject-Independent Evaluation

Florin-Ciprian Argatu, Șerban-Teodor Nicolescu, Felix-Constantin Adochiei, George-Călin Serițan
Sensors
Deception detection and forensic psychology
article

Deception Detection from Five-Channel Wearable EEG on LieWaves: A Reproducible Baseline for Subject-Dependent and Subject-Independent Evaluation

Florin-Ciprian Argatu, Șerban-Teodor Nicolescu, Felix-Constantin Adochiei, George-Călin Serițan
article en

Abstract

Deception detection with low-channel wearable EEG requires protocols that generalize across people while remaining practical for portable devices. Using the public LieWaves dataset (27 subjects recorded with a five-channel Emotiv Insight headset), we evaluate to what extent five-channel head-mounted EEG can support lie-truth discrimination under both subject-independent and subject-dependent evaluations. For the subject-independent setting, we train a compact Residual Network with Squeeze-and-Excitation blocks (ResNet-SE) model on raw overlapping windows with focal loss, light data augmentation, and grouped cross-validation by subject; out-of-fold window probabilities are averaged per session and converted to labels using a single decision threshold estimated from the cross-validated session scores. For the subject-dependent setting, we adopt an overlapping short-window Residual Temporal Convolutional Network with Squeeze-and-Excitation and Attention (Res-TCN-SE-Attention) model that fuses raw EEG with discrete wavelet transform (DWT)-based spectral and handcrafted band-power and Hjorth features, using an 80/10/10 split at the recording/session level (stratified by session label), so that all windows from a given session are assigned to a single subset; because each subject contributes two sessions, the same subject may still appear across subsets via different sessions. The subject-independent model attains 66.70% session-level accuracy with an AUC of 0.58 on unseen subjects, underscoring the difficulty of person-independent generalization from low-channel wearable EEG. Because practical deployment requires generalization to previously unseen individuals, we treat the subject-independent evaluation as the primary estimate of real-world generalization. In contrast, the subject-dependent pipeline reaches 99.94% window-level accuracy under the overlapping sliding-window (OSW) setting with a session-disjoint split (no session contributes windows to more than one subset). This near-ceiling performance reflects the optimistic nature of subject-dependent evaluation with highly overlapping windows, even when avoiding within-session train-test overlap, and should not be interpreted as a meaningful indicator of deception-detection capability under realistic deployment constraints. These results suggest limited, above-chance separability between lie and truth sessions in LieWaves using a five-channel wearable EEG under the studied protocol; however, performance remains far from deployment-ready and is strongly shaped by evaluation design. Explicit reporting of both protocols, together with clear rules for windowing, aggregation, and threshold selection, supports more reproducible and comparable benchmarking.

SensorsVol. 26(3)
Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
National University of Science and Technology
Openalex Percentile: Top 72%
Deception detection and forensic psychology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.