Quantifying the Energy Efficiency, Aging Effects, and Heat Losses of Flat-Plate Solar Collectors in a Temperate Climate

This study evaluates the performance of a flat-plate solar collector thermal system located in Bucharest, Romania, by combining experimental measurements (December 2024–April 2025) with numerical modeling. The system, coupled to a 4000 L tank and using a 30% glycol–water mixture, was monitored for irradiance, wind speed, temperature, flow rate, and humidity. Monthly irradiance averaged 448–584 W/m2, and wind speed 2.3–4.3 m/s. Instantaneous efficiency ranged from 25.09% to 73.25% (mean 52.96%), with CUF (capacity utilization factor) ranging between 6.55% and 9.38%. Total heat losses were 4.80–7.79 kW and dominated by top losses (3.60–5.59 kW). The model reproduced the manufacturer’s efficiency curve within 5% for data obtained in the spring, with winter deviations of up to 37% due to weather variability and aged insulation. The results provide reference values for the CUF and loss coefficients of flat-plate collectors in temperate continental climates and can support retrofit and sizing decisions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-02-04
DOI
https://doi.org/10.3390/en19030817
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying the Energy Efficiency, Aging Effects, and Heat Losses of Flat-Plate Solar Collectors in a Temperate Climate

Teodora Madalina Nichita, Răzvan Calotă, A. Ili, Alina Girip et al.
Energies
Solar Thermal and Photovoltaic Systems
article

Quantifying the Energy Efficiency, Aging Effects, and Heat Losses of Flat-Plate Solar Collectors in a Temperate Climate

Teodora Madalina Nichita, Răzvan Calotă, A. Ili, Alina Girip, Alexandru Panait, Constantin Lazăr
article en

Abstract

This study evaluates the performance of a flat-plate solar collector thermal system located in Bucharest, Romania, by combining experimental measurements (December 2024–April 2025) with numerical modeling. The system, coupled to a 4000 L tank and using a 30% glycol–water mixture, was monitored for irradiance, wind speed, temperature, flow rate, and humidity. Monthly irradiance averaged 448–584 W/m2, and wind speed 2.3–4.3 m/s. Instantaneous efficiency ranged from 25.09% to 73.25% (mean 52.96%), with CUF (capacity utilization factor) ranging between 6.55% and 9.38%. Total heat losses were 4.80–7.79 kW and dominated by top losses (3.60–5.59 kW). The model reproduced the manufacturer’s efficiency curve within 5% for data obtained in the spring, with winter deviations of up to 37% due to weather variability and aged insulation. The results provide reference values for the CUF and loss coefficients of flat-plate collectors in temperate continental climates and can support retrofit and sizing decisions.

EnergiesVol. 19(3)
Technical University of Civil Engineering of Bucharest (RO)
Affordable and clean energy
Openalex Percentile: Top 69%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantifying the Energy Efficiency, Aging Effects, and Heat Losses of Flat-Plate Solar Collectors in a Temperate Climate — Teodora Madalina Nichita, Răzvan Calotă, et al. · Energies (2026) | TGRS Research Map | TGRS