Relating intraocular lens tilt to the optical axes of the eye

An average intraocular lens (IOL) tilt of approximately 5 deg relative to the visual axis is consistently reported in the clinical literature, with the implication that it represents a lens malposition. Modern biometry equipment also now routinely generates "chord" values related to tilt of the eye (chord alpha), and to centration of the pupil (chord mu), with other equipment measuring tilts directly. In this work, clinical data were used to create raytrace eye models, and these show that decentration of the foveal center from the optical axis causes a 5 deg rotation from the optical axis to the visual axis (angle <i>α</i>), with similar values for both phakic and pseudophakic eyes, which explains the apparent lens tilt when viewing along the visual axis. Additional findings include that the iris is modestly decentered nasally from the optical axis, the cornea is typically measured along the keratometric axis but eye models are configured around the optical axis, and that lines drawn at 5 deg angles from the pupils meet at a distance corresponding to near vision. These findings clarify the geometric origin of commonly reported IOL tilt values and have important implications for clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America A
Published
2026-02-03
DOI
https://doi.org/10.1364/josaa.587441
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relating intraocular lens tilt to the optical axes of the eye

Stefan Georgiev, Oliver Findl, Michael A. Simpson
Journal of the Optical Society of America A
Ophthalmology and Visual Impairment Studies
article

Relating intraocular lens tilt to the optical axes of the eye

Stefan Georgiev, Oliver Findl, Michael A. Simpson
article en

Abstract

An average intraocular lens (IOL) tilt of approximately 5 deg relative to the visual axis is consistently reported in the clinical literature, with the implication that it represents a lens malposition. Modern biometry equipment also now routinely generates "chord" values related to tilt of the eye (chord alpha), and to centration of the pupil (chord mu), with other equipment measuring tilts directly. In this work, clinical data were used to create raytrace eye models, and these show that decentration of the foveal center from the optical axis causes a 5 deg rotation from the optical axis to the visual axis (angle <i>α</i>), with similar values for both phakic and pseudophakic eyes, which explains the apparent lens tilt when viewing along the visual axis. Additional findings include that the iris is modestly decentered nasally from the optical axis, the cornea is typically measured along the keratometric axis but eye models are configured around the optical axis, and that lines drawn at 5 deg angles from the pupils meet at a distance corresponding to near vision. These findings clarify the geometric origin of commonly reported IOL tilt values and have important implications for clinical practice.

Journal of the Optical Society of America AVol. 43(3)
Hanusch Hospital (AT)
Openalex Percentile: Top 66%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Relating intraocular lens tilt to the optical axes of the eye — Stefan Georgiev, Oliver Findl, et al. · Journal of the Optical Society of America A (2026) | TGRS Research Map | TGRS