Optimizing Thyroid Nodule Evaluation: AI Integration Into the Thyroid Imaging Reporting and Data System Through AI-Based Ultrasound Image Analysis

Background Thyroid nodules are among the most common endocrine abnormalities, with ultrasound serving as the first-line tool for risk stratification. The American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS) standardizes evaluation but is limited by interobserver variability and the time required for detailed interpretation. Artificial intelligence (AI) offers the opportunity to address these limitations and to automate diagnostic processes and enhance diagnostic accuracy. Objective To develop and evaluate a vision-language AI model for ACR-TIRADS-based risk stratification of thyroid nodules on ultrasound. Methodology This retrospective study analyzed 1,000 thyroid ultrasound images collected between March 2024 and January 2025, of which 139 met the inclusion criteria. Images were annotated according to ACR-TIRADS features (composition, echogenicity, shape, margins, echogenic foci). A vision-language AI model (LLaVA-Med, Microsoft Research, Redmond, WA) was trained using a two-stage strategy that included domain-specific pretraining and fine-tuning on a curated dataset. Diagnostic performance was assessed as a binary classification: suspicious (TR3-TR5) vs. non-suspicious (TR1-TR2). Results The model achieved an accuracy of 67%, sensitivity of 71%, specificity of 53%, and precision of 84.6%. The F1 score is an average of an AI algorithm's precision and recall, used to evaluate the algorithm's predictive performance. Our model achieved an F1 score of 77%, and its performance favored sensitivity, reducing the likelihood of missed malignant nodules, though specificity remained moderate. Conclusion The vision-language AI model trained on ACR-TIRADS features demonstrated promising performance in thyroid nodule risk stratification. Its higher sensitivity and explainable outputs reflect its potential as a supportive screening tool in clinical practice, particularly in settings with limited radiological expertise. Further refinement and multi-institutional validation are warranted.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-03
DOI
https://doi.org/10.7759/cureus.102893
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Thyroid Nodule Evaluation: AI Integration Into the Thyroid Imaging Reporting and Data System Through AI-Based Ultrasound Image Analysis

Hasan Farooq, Muhammad Omer Altaf, Haseeb A. Arif, Muhammad D Asjad et al.
Cureus
Thyroid Cancer Diagnosis and Treatment
article

Optimizing Thyroid Nodule Evaluation: AI Integration Into the Thyroid Imaging Reporting and Data System Through AI-Based Ultrasound Image Analysis

Hasan Farooq, Muhammad Omer Altaf, Haseeb A. Arif, Muhammad D Asjad, Talat Waseem, Hadiya Mian
article en

Abstract

Background Thyroid nodules are among the most common endocrine abnormalities, with ultrasound serving as the first-line tool for risk stratification. The American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS) standardizes evaluation but is limited by interobserver variability and the time required for detailed interpretation. Artificial intelligence (AI) offers the opportunity to address these limitations and to automate diagnostic processes and enhance diagnostic accuracy. Objective To develop and evaluate a vision-language AI model for ACR-TIRADS-based risk stratification of thyroid nodules on ultrasound. Methodology This retrospective study analyzed 1,000 thyroid ultrasound images collected between March 2024 and January 2025, of which 139 met the inclusion criteria. Images were annotated according to ACR-TIRADS features (composition, echogenicity, shape, margins, echogenic foci). A vision-language AI model (LLaVA-Med, Microsoft Research, Redmond, WA) was trained using a two-stage strategy that included domain-specific pretraining and fine-tuning on a curated dataset. Diagnostic performance was assessed as a binary classification: suspicious (TR3-TR5) vs. non-suspicious (TR1-TR2). Results The model achieved an accuracy of 67%, sensitivity of 71%, specificity of 53%, and precision of 84.6%. The F1 score is an average of an AI algorithm's precision and recall, used to evaluate the algorithm's predictive performance. Our model achieved an F1 score of 77%, and its performance favored sensitivity, reducing the likelihood of missed malignant nodules, though specificity remained moderate. Conclusion The vision-language AI model trained on ACR-TIRADS features demonstrated promising performance in thyroid nodule risk stratification. Its higher sensitivity and explainable outputs reflect its potential as a supportive screening tool in clinical practice, particularly in settings with limited radiological expertise. Further refinement and multi-institutional validation are warranted.

CureusVol. 18(2)
National University of Computer and Emerging Sciences (PK), Shalamar Hospital (PK)
Reduced inequalities
Openalex Percentile: Top 69%
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.