Photon-counting CT versus Energy-integrating Detector CT Performance for Various BMI and Tumor Sizes in Lung Cancer

Background Data on the detection of enhancement-related malignant features and applicable scenarios for low-dose ultrahigh-resolution photon-counting CT (PCCT) in lung cancer are lacking. Purpose To compare the benefits of PCCT versus energy-integrating detector (EID) CT at contrast-enhanced chest CT for different populations with lung cancer. Materials and Methods This prospective study enrolled 459 consecutive participants with lesions who underwent either low-dose contrast media PCCT (1 mL/kg at 2 mL/sec) or standard-dose EID CT (1.2 mL/kg at 3 mL/sec) from June to December 2024. The EID CT group was selected using propensity score matching. Images were reconstructed into five section thicknesses (PCCT: 5 mm, 1 mm, 0.4 mm; EID CT: 5 mm, 1 mm). Adverse reactions and contrast-induced acute kidney injury were recorded. Lesion image quality, malignant radiologic features, diagnostic confidence, and subgroup (body mass index [calculated as weight in kilograms divided by height in meters squared], tumor size) were analyzed using a five-point Likert scale. Statistical data were compared using one-way analysis of variance and post hoc comparisons. Results Among 200 participants after propensity score matching (mean age, 61.66 years ± 9.60 [SD]), PCCT reduced radiation and iodine exposure by 66.34% (effective dose, 1.36 mSv vs 4.04 mSv) and 26.57% (iodine load, 20.62 mg vs 28.08 mg; <i>P</i> < .001), respectively, lowering adverse reactions and contrast-induced acute kidney injury (2% [two of 100 participants] vs 9% [nine of 100], <i>P</i> = .03; 1% [one of 100] vs 7% [seven of 100], <i>P</i> = .03). PCCT at 0.4 mm showed higher detection and diagnostic confidence for enhancement-related malignant features (PCCT vs EID CT, 291-340 findings vs 194-255 findings [Likert 5 {IQR, 4-5} vs Likert 3 {IQR, 3-4}]; <i>P</i> < .001) and yielded higher overall image quality (Likert 5 [IQR, 5-5]; <i>P</i> < .05) in normal weight participants and structures within enhanced lesions of less than or equal to 3 cm (Likert 4 [IQR, 3-4] vs Likert 3 [IQR, 3-3]; <i>P</i> < .001). Conclusion PCCT reduced radiation exposure, adverse reactions, and contrast-induced acute kidney injury compared with EID CT. With a 0.4-mm section thickness, PCCT improved overall image quality, detection of enhancement-related malignant features, and diagnostic confidence, making it suitable for various body mass index and small lesions (T1 stage). © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. <i>Supplemental material is available for this article.</i>

Authors

Institutions

Publication Details

Journal
Radiology
Published
2026-02-01
DOI
https://doi.org/10.1148/radiol.251663
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
21.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-counting CT versus Energy-integrating Detector CT Performance for Various BMI and Tumor Sizes in Lung Cancer

Lina Tao, Limin Lei, Yifan Guo, Heng Zhang et al.
1 citations
Radiology
Advanced X-ray and CT Imaging
21.28
article

Photon-counting CT versus Energy-integrating Detector CT Performance for Various BMI and Tumor Sizes in Lung Cancer

Lina Tao, Limin Lei, Yifan Guo, Heng Zhang, Zhihao Wang, Hao Sun, Xiaoxu Guo, Yuhan Zhou, Yajie Wang, Songwei Yue
article en
1 citations

Abstract

Background Data on the detection of enhancement-related malignant features and applicable scenarios for low-dose ultrahigh-resolution photon-counting CT (PCCT) in lung cancer are lacking. Purpose To compare the benefits of PCCT versus energy-integrating detector (EID) CT at contrast-enhanced chest CT for different populations with lung cancer. Materials and Methods This prospective study enrolled 459 consecutive participants with lesions who underwent either low-dose contrast media PCCT (1 mL/kg at 2 mL/sec) or standard-dose EID CT (1.2 mL/kg at 3 mL/sec) from June to December 2024. The EID CT group was selected using propensity score matching. Images were reconstructed into five section thicknesses (PCCT: 5 mm, 1 mm, 0.4 mm; EID CT: 5 mm, 1 mm). Adverse reactions and contrast-induced acute kidney injury were recorded. Lesion image quality, malignant radiologic features, diagnostic confidence, and subgroup (body mass index [calculated as weight in kilograms divided by height in meters squared], tumor size) were analyzed using a five-point Likert scale. Statistical data were compared using one-way analysis of variance and post hoc comparisons. Results Among 200 participants after propensity score matching (mean age, 61.66 years ± 9.60 [SD]), PCCT reduced radiation and iodine exposure by 66.34% (effective dose, 1.36 mSv vs 4.04 mSv) and 26.57% (iodine load, 20.62 mg vs 28.08 mg; <i>P</i> < .001), respectively, lowering adverse reactions and contrast-induced acute kidney injury (2% [two of 100 participants] vs 9% [nine of 100], <i>P</i> = .03; 1% [one of 100] vs 7% [seven of 100], <i>P</i> = .03). PCCT at 0.4 mm showed higher detection and diagnostic confidence for enhancement-related malignant features (PCCT vs EID CT, 291-340 findings vs 194-255 findings [Likert 5 {IQR, 4-5} vs Likert 3 {IQR, 3-4}]; <i>P</i> < .001) and yielded higher overall image quality (Likert 5 [IQR, 5-5]; <i>P</i> < .05) in normal weight participants and structures within enhanced lesions of less than or equal to 3 cm (Likert 4 [IQR, 3-4] vs Likert 3 [IQR, 3-3]; <i>P</i> < .001). Conclusion PCCT reduced radiation exposure, adverse reactions, and contrast-induced acute kidney injury compared with EID CT. With a 0.4-mm section thickness, PCCT improved overall image quality, detection of enhancement-related malignant features, and diagnostic confidence, making it suitable for various body mass index and small lesions (T1 stage). © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. <i>Supplemental material is available for this article.</i>

RadiologyVol. 318(2)
First Affiliated Hospital of Zhengzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 1%
Advanced X-ray and CT Imaging
21.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.