Refractive outcomes and predictability after cataract surgery combined with GATT or Kahook Dual Blade goniotomy

To compare the refractive outcomes and biometric predictability after cataract surgery (PHACO) with those of PHACO combined with GATT and Kahook Dual Blade (KDB) goniotomy. This is a comparative, retrospective, multicenter study. One or both eyes of patients who had undergone PHACO (control group; CG) and those who had undergone combined PHACO and GATT (GI) or KDB (GII) that had been followed for at least 2 months were analyzed. The refraction observed on postoperative day 60 ± 15 was compared with the refraction predicted by the Barrett II Suite using VERION (Alcon, Fort Worth, TX, USA). Possible confounding factors were analyzed using multivariate regression analysis. A total of 292 eyes (CG = 92, GI = 135, and GII = 65) were included. No statistically significant differences were observed among the groups in terms of the means of the absolute variations (expected refraction-manifest refraction) in the sphere (CG = 0.03 ± 0.52 D, GI = -0.01 ± 0.78 D, and GII = -0.21 ± 1.30 D; p = 0.841), cylinder (CG = -0.15 ± 0.49 D, GI = -0.08 ± 1.02 D, and GII = -0.13 ± 0.82 D; p = 0.132), and axis of astigmatism (CG = 7.74 ± 43.31°, GI = 7.98 ± 48.21°, and GII = 14.80 ± 44.08°; p = 0.508). Corneal curvature was the only predictor that achieved statistical significance (p < 0.001); however, only a weak correlation was observed when the final sphere result (r<sup>2</sup> = 0.11) and astigmatism (r<sup>2</sup> = 0.23) were analyzed. The refraction estimated by VERION exhibited high biometric predictability for PHACO and PHACO combined with GATT or KDB. Furthermore, the final refraction was similar for all procedures.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-03
DOI
https://doi.org/10.1038/s41598-026-38240-0
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refractive outcomes and predictability after cataract surgery combined with GATT or Kahook Dual Blade goniotomy

Júlia Maggi Vieira, Ana Cláudia Alves Pereira, Leopoldo Magacho, Marcos Pereira Vianello et al.
Scientific Reports
Ophthalmology and Visual Impairment Studies
article

Refractive outcomes and predictability after cataract surgery combined with GATT or Kahook Dual Blade goniotomy

Júlia Maggi Vieira, Ana Cláudia Alves Pereira, Leopoldo Magacho, Marcos Pereira Vianello, Eduardo Akio Pereira, Bruno Teno, Francisco Lucena-Neto, Cláudia Franco, Bruno M. Faria, Fábio N. Kanadani
article en

Abstract

To compare the refractive outcomes and biometric predictability after cataract surgery (PHACO) with those of PHACO combined with GATT and Kahook Dual Blade (KDB) goniotomy. This is a comparative, retrospective, multicenter study. One or both eyes of patients who had undergone PHACO (control group; CG) and those who had undergone combined PHACO and GATT (GI) or KDB (GII) that had been followed for at least 2 months were analyzed. The refraction observed on postoperative day 60 ± 15 was compared with the refraction predicted by the Barrett II Suite using VERION (Alcon, Fort Worth, TX, USA). Possible confounding factors were analyzed using multivariate regression analysis. A total of 292 eyes (CG = 92, GI = 135, and GII = 65) were included. No statistically significant differences were observed among the groups in terms of the means of the absolute variations (expected refraction-manifest refraction) in the sphere (CG = 0.03 ± 0.52 D, GI = -0.01 ± 0.78 D, and GII = -0.21 ± 1.30 D; p = 0.841), cylinder (CG = -0.15 ± 0.49 D, GI = -0.08 ± 1.02 D, and GII = -0.13 ± 0.82 D; p = 0.132), and axis of astigmatism (CG = 7.74 ± 43.31°, GI = 7.98 ± 48.21°, and GII = 14.80 ± 44.08°; p = 0.508). Corneal curvature was the only predictor that achieved statistical significance (p < 0.001); however, only a weak correlation was observed when the final sphere result (r<sup>2</sup> = 0.11) and astigmatism (r<sup>2</sup> = 0.23) were analyzed. The refraction estimated by VERION exhibited high biometric predictability for PHACO and PHACO combined with GATT or KDB. Furthermore, the final refraction was similar for all procedures.

Scientific ReportsVol. 16(1)
Universidade Federal de Mato Grosso do Sul (BR), Hospital de Base (BR), WinnMed (US), Universidade Federal do Rio Grande do Norte (BR), Mayo Clinic in Florida (US), Universidade Federal de Goiás (BR), Universidade Federal de São Paulo (BR)
Openalex Percentile: Top 66%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.