Detecting and understanding the dynamics of blood coagulation on a material’s surface: An optical reflectance approach

Despite the technological advancement in blood-contacting biomedical devices, issues related to thrombosis remain a persistent challenge. These devices not only include implants such as artificial heart valves and stents but also surgical tools and instruments. This makes hemocompatibility an important parameter to be considered before developing any material for a blood-contacting device. The two oldest methods, including the mechanical tilting method and the free-hemoglobin method, lack temporal accuracy and quantitative analysis. Our work gives an accurate and quantitative analysis to measure the blood clotting time of various materials that can be used as implant devices. The system relies on measuring the change of reflectance as blood clots on a surface and measures the clotting time and rate by analyzing the time dependent reflectance curve. The system consists of an automated injection system, a heater and temperature controller, a red laser and polarizer assembly, and a highly sensitive photodetector. As the blood clotting process begins, the sample surface becomes turbid, causing a change in voltage in the detector. The time taken for this "voltage change" corresponds to clotting time. Our system shows a prothrombin time of 12.6 s and an activated partial thromboplastin time of 31.16 s on the PTFE surface, close to the control due to its hydrophobicity. The electronics and device configuration used in our system give a temporal resolution of 5.7 ± 0.6 ms in the clotting time determination. Our design is compact, precise, accurate, and devoid of manual observation and errors.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0303413
Primary Topic
Hemoglobin structure and function
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting and understanding the dynamics of blood coagulation on a material’s surface: An optical reflectance approach

Somnath C. Roy, Govinda Chandra Behera, Vignesh Muthuvijayan, Subhashree Mishra
Review of Scientific Instruments
Hemoglobin structure and function
article

Detecting and understanding the dynamics of blood coagulation on a material’s surface: An optical reflectance approach

Somnath C. Roy, Govinda Chandra Behera, Vignesh Muthuvijayan, Subhashree Mishra
article en

Abstract

Despite the technological advancement in blood-contacting biomedical devices, issues related to thrombosis remain a persistent challenge. These devices not only include implants such as artificial heart valves and stents but also surgical tools and instruments. This makes hemocompatibility an important parameter to be considered before developing any material for a blood-contacting device. The two oldest methods, including the mechanical tilting method and the free-hemoglobin method, lack temporal accuracy and quantitative analysis. Our work gives an accurate and quantitative analysis to measure the blood clotting time of various materials that can be used as implant devices. The system relies on measuring the change of reflectance as blood clots on a surface and measures the clotting time and rate by analyzing the time dependent reflectance curve. The system consists of an automated injection system, a heater and temperature controller, a red laser and polarizer assembly, and a highly sensitive photodetector. As the blood clotting process begins, the sample surface becomes turbid, causing a change in voltage in the detector. The time taken for this "voltage change" corresponds to clotting time. Our system shows a prothrombin time of 12.6 s and an activated partial thromboplastin time of 31.16 s on the PTFE surface, close to the control due to its hydrophobicity. The electronics and device configuration used in our system give a temporal resolution of 5.7 ± 0.6 ms in the clotting time determination. Our design is compact, precise, accurate, and devoid of manual observation and errors.

Review of Scientific InstrumentsVol. 97(2)
Indian Institute of Technology Madras (IN)
Openalex Percentile: Top 70%
Hemoglobin structure and function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detecting and understanding the dynamics of blood coagulation on a material’s surface: An optical reflectance approach — Somnath C. Roy, Govinda Chandra Behera, et al. · Review of Scientific Instruments (2026) | TGRS Research Map | TGRS