The influence of different surface texture parameters on the cell proliferation and adhesion early behaviors on the surface of titanium alloy

Current clinical practice has extensively validated the efficacy of left ventricular assist devices (LVADs) in managing end-stage heart failure. A persistent challenge across all ventricular assist systems involves achieving optimal biocompatibility at the critical interface between the LVAD outlet and myocardial tissue. In this study, femtosecond laser processing (FLP) technology was utilized to engineer microtextured surfaces with controlled geometric parameters on the titanium alloy surface. The experimental design systematically assessed surface morphology and compositional variations for four distinct patterns (circular, triangular, square, hexagonal) and three texture depths (10, 20, 40 μm). FLP demonstrated favourable microstructural fabrication quality, producing defined pattern boundaries with minimal thermal impact on adjacent regions. While all textured surfaces exhibited characteristic periodic processing marks at their bases, increased texture depth correlated with progressive roughness amplification in these basal regions. Elemental analysis revealed that oxygen enrichment specifically along texture peripheries compared to untextured surfaces. Cellular early response studies demonstrated that surface texturing significantly enhanced cardiac fibroblasts adhesion on titanium substrates while concurrently modifying fibroblast growth patterns. Quantitative analysis identified 20 μm as the optimal texture depth for cellular proliferation and adhesion, outperforming both shallower (10 μm) and deeper (40 μm) configurations. Geometric comparisons indicated that square patterns induced the best pronounced pro-proliferative effects, followed by hexagonal patterns. Mechanistic observations suggest that surface micro-roughness facilitates initial cell adhesion, with subsequent proliferation biodynamics being governed by topographical guidance effects. These findings establish clear structure-function relationships between engineered surface parameters and biological responses, providing significant insights for LVAD surface treatment and optimization.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-02-03
DOI
https://doi.org/10.3389/fbioe.2026.1679515
Primary Topic
Tissue Engineering and Regenerative Medicine
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The influence of different surface texture parameters on the cell proliferation and adhesion early behaviors on the surface of titanium alloy

W. Liu, Lukui Chen, Yong Li, Chuang Cao et al.
Frontiers in Bioengineering and Biotechnology
Tissue Engineering and Regenerative Medicine
article

The influence of different surface texture parameters on the cell proliferation and adhesion early behaviors on the surface of titanium alloy

W. Liu, Lukui Chen, Yong Li, Chuang Cao, Zhihuang Qiu, Fuqiang Lai, Linfeng Xie, Mengfan Shang
article en

Abstract

Current clinical practice has extensively validated the efficacy of left ventricular assist devices (LVADs) in managing end-stage heart failure. A persistent challenge across all ventricular assist systems involves achieving optimal biocompatibility at the critical interface between the LVAD outlet and myocardial tissue. In this study, femtosecond laser processing (FLP) technology was utilized to engineer microtextured surfaces with controlled geometric parameters on the titanium alloy surface. The experimental design systematically assessed surface morphology and compositional variations for four distinct patterns (circular, triangular, square, hexagonal) and three texture depths (10, 20, 40 μm). FLP demonstrated favourable microstructural fabrication quality, producing defined pattern boundaries with minimal thermal impact on adjacent regions. While all textured surfaces exhibited characteristic periodic processing marks at their bases, increased texture depth correlated with progressive roughness amplification in these basal regions. Elemental analysis revealed that oxygen enrichment specifically along texture peripheries compared to untextured surfaces. Cellular early response studies demonstrated that surface texturing significantly enhanced cardiac fibroblasts adhesion on titanium substrates while concurrently modifying fibroblast growth patterns. Quantitative analysis identified 20 μm as the optimal texture depth for cellular proliferation and adhesion, outperforming both shallower (10 μm) and deeper (40 μm) configurations. Geometric comparisons indicated that square patterns induced the best pronounced pro-proliferative effects, followed by hexagonal patterns. Mechanistic observations suggest that surface micro-roughness facilitates initial cell adhesion, with subsequent proliferation biodynamics being governed by topographical guidance effects. These findings establish clear structure-function relationships between engineered surface parameters and biological responses, providing significant insights for LVAD surface treatment and optimization.

Frontiers in Bioengineering and BiotechnologyVol. 14
Fujian Medical University (CN), Fuzhou University (CN)
National Natural Science Foundation of China, Fujian Medical University
Openalex Percentile: Top 68%
Tissue Engineering and Regenerative Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.