Accuracy of CAD/CAM planned mandibular reconstruction with scapula free flaps in reconstructive head and neck surgery – A single center study

For the first time, this study explores the transfer precision of computer aided design and computer aided manufacturing (CAD/CAM) in mandibular reconstruction with scapula free flaps (SFF). Patients undergoing mandibular reconstruction with SFF and patient-specific 3D-printed titanium plates were retrospectively analyzed. To assess planning accuracy, pre- and postoperative datasets were overlaid using 3D Slicer software. Specific measurements included the fit at the mandibular resection site, intersegmental gap width between scapula and mandible, scapular segment positioning, and condylar alignment. Osseous union was evaluated via postoperative computed tomography (CT) or cone beam CT, and plate-related complications were recorded clinically. In total 15 patients (mean age 65.7 ± 10.0 years) were included. Postoperative scapular segment positioning showed deviations in the posterior region (basal: 6.78 ± 3.34 mm; crestal: 7.61 ± 3.40 mm) and anterior region (basal: 3.54 ± 1.52 mm; crestal: 4.49 ± 2.51 mm). Mean deviation in segmental gap width at the anterior and posterior sites ranged from 0.55 to 1.72 mm and was statistically significant at all four measurements. Mean contralateral condyle position differed significantly from the initial position (8.56 ± 4.31 mm). Intraoral plate exposure occurred in three patients without adjuvant radiotherapy; no extraoral exposure, fractures, or loosening were observed. Non-union between the mandible and SFF was found in three patients. As with other CAD/CAM-assisted mandibular reconstructions, SFF exhibit discrepancies between virtual planning and the postoperative outcome. The surrounding soft tissue bulk of the scapula can hinder the precise fit of cutting guides, potentially compromising reconstruction accuracy and contributing to increased deviations. Despite these challenges, CAD/CAM-assisted SFF demonstrates acceptable surgical predictability.

Authors

Institutions

Publication Details

Journal
Oral and Maxillofacial Surgery
Published
2026-02-04
DOI
https://doi.org/10.1007/s10006-026-01505-z
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of CAD/CAM planned mandibular reconstruction with scapula free flaps in reconstructive head and neck surgery – A single center study

Claudius Steffen, Christian Doll, Norbert Neckel, Carsten Rendenbach et al.
Oral and Maxillofacial Surgery
Reconstructive Surgery and Microvascular Techniques
article

Accuracy of CAD/CAM planned mandibular reconstruction with scapula free flaps in reconstructive head and neck surgery – A single center study

Claudius Steffen, Christian Doll, Norbert Neckel, Carsten Rendenbach, Tim Elter, Jakob Fenske, Steffen Koerdt, Kilian Kreutzer, Jonas Wüster, Max Heiland, Max Brandenburg
article en

Abstract

For the first time, this study explores the transfer precision of computer aided design and computer aided manufacturing (CAD/CAM) in mandibular reconstruction with scapula free flaps (SFF). Patients undergoing mandibular reconstruction with SFF and patient-specific 3D-printed titanium plates were retrospectively analyzed. To assess planning accuracy, pre- and postoperative datasets were overlaid using 3D Slicer software. Specific measurements included the fit at the mandibular resection site, intersegmental gap width between scapula and mandible, scapular segment positioning, and condylar alignment. Osseous union was evaluated via postoperative computed tomography (CT) or cone beam CT, and plate-related complications were recorded clinically. In total 15 patients (mean age 65.7 ± 10.0 years) were included. Postoperative scapular segment positioning showed deviations in the posterior region (basal: 6.78 ± 3.34 mm; crestal: 7.61 ± 3.40 mm) and anterior region (basal: 3.54 ± 1.52 mm; crestal: 4.49 ± 2.51 mm). Mean deviation in segmental gap width at the anterior and posterior sites ranged from 0.55 to 1.72 mm and was statistically significant at all four measurements. Mean contralateral condyle position differed significantly from the initial position (8.56 ± 4.31 mm). Intraoral plate exposure occurred in three patients without adjuvant radiotherapy; no extraoral exposure, fractures, or loosening were observed. Non-union between the mandible and SFF was found in three patients. As with other CAD/CAM-assisted mandibular reconstructions, SFF exhibit discrepancies between virtual planning and the postoperative outcome. The surrounding soft tissue bulk of the scapula can hinder the precise fit of cutting guides, potentially compromising reconstruction accuracy and contributing to increased deviations. Despite these challenges, CAD/CAM-assisted SFF demonstrates acceptable surgical predictability.

Oral and Maxillofacial SurgeryVol. 30(1)
University of Freiburg (DE), University Medical Center Freiburg (DE), Humboldt-Universität zu Berlin (DE), Freie Universität Berlin (DE), Charité - Universitätsmedizin Berlin (DE)
Sustainable cities and communities
Openalex Percentile: Top 68%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.