Evaluation of the Effect of Different Contaminants on the Reverse Torque Values at the Implant Abutment Junction: An In Vitro Study

Abstract Screw loosening at the implant-abutment junction is the commonest failure reason of implant prosthesis. This happens mainly due to improper insertion torque and friction between the clamping surfaces. This article evaluates the effect of three different contaminants on the screw loosening at the implant abutment junction. This effect is measured as reverse torque value, that is, the force required to loosen the screw after the contamination is done. Saliva, titanium nanoparticles, and sodium fluoride are used as contaminants which were prepared as 1000 ppm solutions with artificial saliva as a solvent. Thirty Genesis Aktiv Internal hex parallel implants were divided into three groups and contaminated in their screw access channel with the respective contaminants and clamped with straight abutments at 35 Ncm. They were torqued again after 10 minutes to compensate for settling effect. After that, they are stored in artificial saliva for 14 days at 37°C. Reverse torque values were measured by a physiodispenser. The data collected was subjected to one-way analysis of variance test to determine the difference between groups. Tukey post hoc analysis was done to evaluate the intergroup mean differences. A statistically significant difference was noted in the mean reverse torque values between group 1 and groups 2 and 3. But, when intergroup comparisons were made, the difference between group 1 and group 2 only had statistical significance. The reverse torque values increased significantly when contaminated with sodium fluoride and titanium nanoparticle solutions, which can be attributed the reduced friction between the clamping surfaces, thereby negating the settling effect.

Authors

Institutions

Publication Details

Journal
European Journal of General Dentistry
Published
2026-02-03
DOI
https://doi.org/10.1055/s-0045-1813027
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Effect of Different Contaminants on the Reverse Torque Values at the Implant Abutment Junction: An In Vitro Study

Chandrika Chinta, Sreeramulu Basapogu, Vineela Pyla, Bharat Chandra Velamakuri et al.
European Journal of General Dentistry
Dental Implant Techniques and Outcomes
article

Evaluation of the Effect of Different Contaminants on the Reverse Torque Values at the Implant Abutment Junction: An In Vitro Study

Chandrika Chinta, Sreeramulu Basapogu, Vineela Pyla, Bharat Chandra Velamakuri, Boyapati Ramanarayana
article en

Abstract

Abstract Screw loosening at the implant-abutment junction is the commonest failure reason of implant prosthesis. This happens mainly due to improper insertion torque and friction between the clamping surfaces. This article evaluates the effect of three different contaminants on the screw loosening at the implant abutment junction. This effect is measured as reverse torque value, that is, the force required to loosen the screw after the contamination is done. Saliva, titanium nanoparticles, and sodium fluoride are used as contaminants which were prepared as 1000 ppm solutions with artificial saliva as a solvent. Thirty Genesis Aktiv Internal hex parallel implants were divided into three groups and contaminated in their screw access channel with the respective contaminants and clamped with straight abutments at 35 Ncm. They were torqued again after 10 minutes to compensate for settling effect. After that, they are stored in artificial saliva for 14 days at 37°C. Reverse torque values were measured by a physiodispenser. The data collected was subjected to one-way analysis of variance test to determine the difference between groups. Tukey post hoc analysis was done to evaluate the intergroup mean differences. A statistically significant difference was noted in the mean reverse torque values between group 1 and groups 2 and 3. But, when intergroup comparisons were made, the difference between group 1 and group 2 only had statistical significance. The reverse torque values increased significantly when contaminated with sodium fluoride and titanium nanoparticle solutions, which can be attributed the reduced friction between the clamping surfaces, thereby negating the settling effect.

European Journal of General Dentistry
Niloufer Hospital (IN), Yashoda Hospital (IN), Government Dental College and Hospital (IN), MNR Dental College and Hospital (IN), Kamineni Institute of Dental Sciences (IN)
Openalex Percentile: Top 69%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.