Investigation of Transients Generated by Dry-Contact Switching of LED Lamps

LED lamps have not been demonstrating the durability claimed by their manufacturers. One hypothesis is that switching transients may contribute to this. This study investigated switching-induced transients in LED lamps operated through dry contacts: manual switches and contactors. Using an oscilloscope, automated acquisition of waveform records was performed while several lamps were switched on in a 220 VRMS/60 Hz electrical network. LED lamps of different models and manufacturers, one incandescent lamp, and a group of 48 LED lamps, subdivided into six sets of eight lamps, were all switched simultaneously. A total of 56 waveform-record files were obtained from the oscilloscope, comprising 2920 captured screens and 170 measurements. Transient voltage peaks of 380 and 391 V at the supply side, and 357 and 370 V at the lamp side, as well as voltage slew rates of up to 12 and 13 V/µs at the supply side and up to 16 and 19.5 V/µs at the lamp side, were measured, without considering statistical variations, which may indicate values exceeding the ordinary sinusoidal voltage peak (≅311 V) and its typical worst-case slew rate (≅0.12 V/µs). Future studies are suggested, such as tests in real installations, investigations of transient amplification or attenuation within electrical networks, assessment of the effects of wiring and impedance discontinuities, switch bounce, and semiconductor degradation, among others, to continue these studies.

Authors

Institutions

Publication Details

Journal
Electricity
Published
2026-02-03
DOI
https://doi.org/10.3390/electricity7010013
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Transients Generated by Dry-Contact Switching of LED Lamps

Ângelo Marcelo Tusset, Alisson L. Agusti, Giane G. Lenzi, Jose M. Balthazar
Electricity
Advanced DC-DC Converters
article

Investigation of Transients Generated by Dry-Contact Switching of LED Lamps

Ângelo Marcelo Tusset, Alisson L. Agusti, Giane G. Lenzi, Jose M. Balthazar
article en

Abstract

LED lamps have not been demonstrating the durability claimed by their manufacturers. One hypothesis is that switching transients may contribute to this. This study investigated switching-induced transients in LED lamps operated through dry contacts: manual switches and contactors. Using an oscilloscope, automated acquisition of waveform records was performed while several lamps were switched on in a 220 VRMS/60 Hz electrical network. LED lamps of different models and manufacturers, one incandescent lamp, and a group of 48 LED lamps, subdivided into six sets of eight lamps, were all switched simultaneously. A total of 56 waveform-record files were obtained from the oscilloscope, comprising 2920 captured screens and 170 measurements. Transient voltage peaks of 380 and 391 V at the supply side, and 357 and 370 V at the lamp side, as well as voltage slew rates of up to 12 and 13 V/µs at the supply side and up to 16 and 19.5 V/µs at the lamp side, were measured, without considering statistical variations, which may indicate values exceeding the ordinary sinusoidal voltage peak (≅311 V) and its typical worst-case slew rate (≅0.12 V/µs). Future studies are suggested, such as tests in real installations, investigations of transient amplification or attenuation within electrical networks, assessment of the effects of wiring and impedance discontinuities, switch bounce, and semiconductor degradation, among others, to continue these studies.

ElectricityVol. 7(1)
Universidade Tecnológica Federal do Paraná (BR), Instituto Federal de Educação, Ciência e Tecnologia de Santa Catarina (BR), Universidade Estadual de Ponta Grossa (BR), Universidade Estadual Paulista (Unesp) (BR)
Openalex Percentile: Top 68%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.