In Vitro Mechanical Study of Three-Dimensional Printed Invisible Dental Aligners for Crowded Dentition Problems: A Patient-Specific Study

Clear aligners are a popular alternative to fixed orthodontic appliances; however, technical data on the optimal final aligner shell thickness for directly printed aligners remain limited. This in vitro experimental pilot study evaluated the mechanical response of patient-specific, directly 3D-printed aligners of four nominal shell thicknesses (0.04, 0.06, 0.08, and 0.10 mm) fabricated from BioMed Clear resin. A single subject with dental crowding was scanned and a set of aligner shells was designed and printed (<i>n</i> = 3 per thickness). Compressive tests up to 1000 N were performed and compressive extension (mm) recorded; group means ± SD were compared by means of one-way ANOVA. No statistically significant differences in compressive extension were found among the four thickness groups (ANOVA, F(3,8) = 2.242, <i>p</i> = 0.161). The 0.08 mm group showed a lower mean compressive extension in this dataset, but the difference did not reach statistical significance; given the small sample size and single-subject nature of the study, this result should be considered exploratory. This recent study clarifies printing and post-processing parameters and highlights limitations and directions for future work.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2026-02-03
DOI
https://doi.org/10.3390/biomimetics11020108
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Mechanical Study of Three-Dimensional Printed Invisible Dental Aligners for Crowded Dentition Problems: A Patient-Specific Study

Hong-Seng Gan, Muhammad Hanif Ramlee, Zelafy Reynosa
Biomimetics
Orthodontics and Dentofacial Orthopedics
article

In Vitro Mechanical Study of Three-Dimensional Printed Invisible Dental Aligners for Crowded Dentition Problems: A Patient-Specific Study

Hong-Seng Gan, Muhammad Hanif Ramlee, Zelafy Reynosa
article en

Abstract

Clear aligners are a popular alternative to fixed orthodontic appliances; however, technical data on the optimal final aligner shell thickness for directly printed aligners remain limited. This in vitro experimental pilot study evaluated the mechanical response of patient-specific, directly 3D-printed aligners of four nominal shell thicknesses (0.04, 0.06, 0.08, and 0.10 mm) fabricated from BioMed Clear resin. A single subject with dental crowding was scanned and a set of aligner shells was designed and printed (<i>n</i> = 3 per thickness). Compressive tests up to 1000 N were performed and compressive extension (mm) recorded; group means ± SD were compared by means of one-way ANOVA. No statistically significant differences in compressive extension were found among the four thickness groups (ANOVA, F(3,8) = 2.242, <i>p</i> = 0.161). The 0.08 mm group showed a lower mean compressive extension in this dataset, but the difference did not reach statistical significance; given the small sample size and single-subject nature of the study, this result should be considered exploratory. This recent study clarifies printing and post-processing parameters and highlights limitations and directions for future work.

BiomimeticsVol. 11(2)
University of Technology Malaysia (MY), Xi’an Jiaotong-Liverpool University (CN)
Openalex Percentile: Top 67%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.