Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner

The contribution of persistent inward currents (PICs) to motoneuron firing in the lower limb typically increases after a remote handgrip contraction, believed to result from diffuse serotonergic input increases in spinal cord. We investigated whether handgrip contraction intensity, duration and/or impulse would affect PIC estimates in tibialis anterior motoneurons. Multi-channel electromyograms were recorded from the tibialis anterior of 21 participants (18-40 years), during dorsiflexions at 20% of the individuals' maximal torque, before and after four handgrip conditions: (i) 80% of their maximal handgrip strength sustained for 15 s (80%15s); (ii) 40% sustained for 15 s (40%15s); (iii) 40% sustained for 30 s (40%30s); and (iv) no handgrip (Control). The PIC contribution to self-sustained motoneuron firing was estimated with delta frequency (ΔF) using paired motor unit analysis. The 'brace height', normalised as a percentage of a right triangle (% rTri), was used to estimate the PIC effects on the non-linearity of firing patterns, representing the neuromodulatory drive (metabotropic regulation of motoneuron excitability) onto the motoneurons. ΔF increased by 0.33 pulses per second (pps; 95% CI: 0.16-0.49, d = 0.47) after 40%30s and by 0.24 pps (0.09-0.38, d = 0.34) after 80%15s, but remained unchanged after 40%15s and Control. Similarly, brace height increased by 2.24% rTri (0.18-4.30, d = 0.20) after 40%30s and by 2.45% rTri (0.64-4.25, d = 0.22) after 80%15s, remaining unchanged after 40%15s and Control. The increase in the PIC contribution to motoneuron firing induced by a remote handgrip contraction is impulse dependent rather than intensity or duration dependent. The parallel increases in ΔF and brace height suggest augmented neuromodulatory input onto the spinal cord.

Authors

Institutions

Publication Details

Journal
Experimental Physiology
Published
2026-02-03
DOI
https://doi.org/10.1113/ep092961
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner

Lucas Ugliara, Gabriel S. Trajano, Lucas B. R. Orssatto, Amilton Vieira
Experimental Physiology
Muscle activation and electromyography studies
article

Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner

Lucas Ugliara, Gabriel S. Trajano, Lucas B. R. Orssatto, Amilton Vieira
article en

Abstract

The contribution of persistent inward currents (PICs) to motoneuron firing in the lower limb typically increases after a remote handgrip contraction, believed to result from diffuse serotonergic input increases in spinal cord. We investigated whether handgrip contraction intensity, duration and/or impulse would affect PIC estimates in tibialis anterior motoneurons. Multi-channel electromyograms were recorded from the tibialis anterior of 21 participants (18-40 years), during dorsiflexions at 20% of the individuals' maximal torque, before and after four handgrip conditions: (i) 80% of their maximal handgrip strength sustained for 15 s (80%15s); (ii) 40% sustained for 15 s (40%15s); (iii) 40% sustained for 30 s (40%30s); and (iv) no handgrip (Control). The PIC contribution to self-sustained motoneuron firing was estimated with delta frequency (ΔF) using paired motor unit analysis. The 'brace height', normalised as a percentage of a right triangle (% rTri), was used to estimate the PIC effects on the non-linearity of firing patterns, representing the neuromodulatory drive (metabotropic regulation of motoneuron excitability) onto the motoneurons. ΔF increased by 0.33 pulses per second (pps; 95% CI: 0.16-0.49, d = 0.47) after 40%30s and by 0.24 pps (0.09-0.38, d = 0.34) after 80%15s, but remained unchanged after 40%15s and Control. Similarly, brace height increased by 2.24% rTri (0.18-4.30, d = 0.20) after 40%30s and by 2.45% rTri (0.64-4.25, d = 0.22) after 80%15s, remaining unchanged after 40%15s and Control. The increase in the PIC contribution to motoneuron firing induced by a remote handgrip contraction is impulse dependent rather than intensity or duration dependent. The parallel increases in ΔF and brace height suggest augmented neuromodulatory input onto the spinal cord.

Experimental Physiology
Universidade de Brasília (BR), Queensland University of Technology (AU), The University of Queensland (AU)
Openalex Percentile: Top 69%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.