Tanshinone IIA / PCL nanofiber-covered airway stent inhibits tracheal stenosis

Mechanical injury is the primary initiating cause of iatrogenic tracheal stenosis (TS), while bacterial infection and persistent inflammatory responses are crucial exacerbating factors driving fibrotic progression. In this study, we constructed a Tanshinone IIA / PCL nanofiber-covered airway stent (PCL@Tan-IIA) using electrospinning technology. Characterizations revealed that the PCL@Tan-IIA stent possessed hydrophobic surface characteristics, favorable mechanical strength, and desirable drug-release kinetics, coupled with potent antibacterial efficacy against planktonic methicillin-resistant Staphylococcus aureus (MRSA). Mechanistically, the stent exerted anti-inflammatory activity by downregulating the secretion of pro-inflammatory cytokine IL-6 and upregulating the expression of anti-inflammatory cytokine IL-10 in macrophages. Concurrently, it exhibited anti-fibrotic effects through inhibiting the migration and activation of human pulmonary fibroblasts. Moreover, the PCL@Tan-IIA stent implanted in New Zealand rabbits inhibited local airway bacterial proliferation, alleviated inflammation and reduced excessive fibrous tissue hyperplasia. This work provides a promising strategy to overcome stent-induced restenosis and has potential for clinical translation in the management of TS. Scheme 1. Preparation process and mechanism of PCL@Tan-IIA airway stent. (A) PCL is dissolved and blended with Tan-IIA, and the mixture is processed via electrospinning to fabricate the PCL@Tan-IIA airway stent. (B) Guided by C-Arm digital subtraction angiography (C-Arm DSA), stent implantation effectively inhibits tracheal stenosis. (C) The stent exerts multidimensional therapeutic effects—including anti-bacterial, anti-inflammatory, and anti-fibrotic actions—thereby improving airway pathology comprehensively.

Authors

Institutions

Publication Details

Journal
Materials Today Communications
Published
2026-02-01
DOI
https://doi.org/10.1016/j.mtcomm.2026.114778
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tanshinone IIA / PCL nanofiber-covered airway stent inhibits tracheal stenosis

Chengzhi Zhang, Jiheng Shan, Yilin Liu, Jianzhuang Ren et al.
Materials Today Communications
Tracheal and airway disorders
article

Tanshinone IIA / PCL nanofiber-covered airway stent inhibits tracheal stenosis

Chengzhi Zhang, Jiheng Shan, Yilin Liu, Jianzhuang Ren, Kewei Ren, Erlong Li, Junheng Zhang, Yingjuan Zheng, Yiran Wang, Xinwei Han
article en

Abstract

Mechanical injury is the primary initiating cause of iatrogenic tracheal stenosis (TS), while bacterial infection and persistent inflammatory responses are crucial exacerbating factors driving fibrotic progression. In this study, we constructed a Tanshinone IIA / PCL nanofiber-covered airway stent (PCL@Tan-IIA) using electrospinning technology. Characterizations revealed that the PCL@Tan-IIA stent possessed hydrophobic surface characteristics, favorable mechanical strength, and desirable drug-release kinetics, coupled with potent antibacterial efficacy against planktonic methicillin-resistant Staphylococcus aureus (MRSA). Mechanistically, the stent exerted anti-inflammatory activity by downregulating the secretion of pro-inflammatory cytokine IL-6 and upregulating the expression of anti-inflammatory cytokine IL-10 in macrophages. Concurrently, it exhibited anti-fibrotic effects through inhibiting the migration and activation of human pulmonary fibroblasts. Moreover, the PCL@Tan-IIA stent implanted in New Zealand rabbits inhibited local airway bacterial proliferation, alleviated inflammation and reduced excessive fibrous tissue hyperplasia. This work provides a promising strategy to overcome stent-induced restenosis and has potential for clinical translation in the management of TS. Scheme 1. Preparation process and mechanism of PCL@Tan-IIA airway stent. (A) PCL is dissolved and blended with Tan-IIA, and the mixture is processed via electrospinning to fabricate the PCL@Tan-IIA airway stent. (B) Guided by C-Arm digital subtraction angiography (C-Arm DSA), stent implantation effectively inhibits tracheal stenosis. (C) The stent exerts multidimensional therapeutic effects—including anti-bacterial, anti-inflammatory, and anti-fibrotic actions—thereby improving airway pathology comprehensively.

Materials Today CommunicationsVol. 51
Zhengzhou University (CN), First Affiliated Hospital of Zhengzhou University (CN)
Openalex Percentile: Top 69%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.