Factors Affecting the Functioning of Critical Medical Equipment in a Tertiary Care Hospital

Objective In this study, we aimed to estimate the mean downtime of the commonly used equipment and to identify the causes of their downtime in a tertiary care hospital. Methods Data were collected through retrospective record analysis of commonly used hospital equipment over two years, followed by prospective data collection on the same equipment over six months to capture key maintenance parameters. Results The average downtime index for all equipment was 8.78%. It was observed that cardiac monitors had the maximum downtime at 41.8%. The main causes of downtime were inadequate maintenance at 25.28%, product failure at 14.94%, and mishandling at 14.18%. Conclusions It was observed that newer equipment experienced less downtime. A lack of spares and accessory inventory in both hospital stores and with vendors contributed to downtime. Given staff turnover and a lack of reinforcement, personnel operating the equipment were often without adequate operational knowledge. Some good maintenance practices identified included the provision of extra accessories by vendors in accordance with the terms and conditions of the tender. The main causes of downtime were inadequate maintenance, product failure, and mishandling, which together accounted for nearly half of all causes.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-03
DOI
https://doi.org/10.7759/cureus.102926
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Affecting the Functioning of Critical Medical Equipment in a Tertiary Care Hospital

Amit Lathwal, Nirupam Madaan, Anant Gupta
Cureus
Quality and Safety in Healthcare
article

Factors Affecting the Functioning of Critical Medical Equipment in a Tertiary Care Hospital

Amit Lathwal, Nirupam Madaan, Anant Gupta
article en

Abstract

Objective In this study, we aimed to estimate the mean downtime of the commonly used equipment and to identify the causes of their downtime in a tertiary care hospital. Methods Data were collected through retrospective record analysis of commonly used hospital equipment over two years, followed by prospective data collection on the same equipment over six months to capture key maintenance parameters. Results The average downtime index for all equipment was 8.78%. It was observed that cardiac monitors had the maximum downtime at 41.8%. The main causes of downtime were inadequate maintenance at 25.28%, product failure at 14.94%, and mishandling at 14.18%. Conclusions It was observed that newer equipment experienced less downtime. A lack of spares and accessory inventory in both hospital stores and with vendors contributed to downtime. Given staff turnover and a lack of reinforcement, personnel operating the equipment were often without adequate operational knowledge. Some good maintenance practices identified included the provision of extra accessories by vendors in accordance with the terms and conditions of the tender. The main causes of downtime were inadequate maintenance, product failure, and mishandling, which together accounted for nearly half of all causes.

CureusVol. 18(2)
All India Institute of Medical Sciences (IN)
Openalex Percentile: Top 75%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Factors Affecting the Functioning of Critical Medical Equipment in a Tertiary Care Hospital — Amit Lathwal, Nirupam Madaan, et al. · Cureus (2026) | TGRS Research Map | TGRS