Elevated airborne submicron particle counts linked to direct evaporative cooling in greenhouses

• Direct evaporative cooling elevated airborne nanoparticle counts in greenhouses • The counts increased markedly from 0.15 m to 2.0 m downstream of cooling pads • Evaporation of saline droplets in greenhouses contributed to nanoparticle formation • Gas-particle conversion due to lower temperature and higher humidity is also likely Direct evaporative cooling (DEC) systems are widely used for climate control in agricultural, industrial, and residential environments. However, prolonged operation can lead to mineral scaling and biofilm fouling on cooling pads. To mitigate these issues, chemical additives are commonly introduced into the recirculating water. During system operation, fine saline droplets, similar to those produced by atomization, may contribute to airborne submicron particle (SP) formation, a phenomenon not yet investigated. This study compared airborne SP counts and size distributions in a greenhouse during active versus idle periods and accessed spatial distributions using three outdoor and nine indoor monitoring locations. Results revealed that indoor SP counts averaged 3,117±223 particles/cm 3 with the DEC system off and increased to 3,437±720 particles/cm 3 when on, as measured using a TSI NanoScan SMPS. Similar trends were observed using a CPC 3007 (off: 5,369±271 particles/cm 3 ; on: 6,416±1,128 particles/cm 3 ). SP counts increased significantly from 0.15 m downstream of the cooling pads to 2.1 m downstream, followed by a slight decrease at 4.0 m. This pattern contrasts with the gradual decline observed at these locations when the system was off. Particle size analysis revealed increased SP counts at 2.0 m downstream primarily occurred in the 11.5-27.5 nm, consistent with nanoparticles generated via atomization of diluted salt solutions. Overall, findings indicate that DEC operation can elevate airborne SP concentrations in built environments.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials Advances
Published
2026-02-01
DOI
https://doi.org/10.1016/j.hazadv.2026.101053
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elevated airborne submicron particle counts linked to direct evaporative cooling in greenhouses

Seyit Uğuz, Mazhar Sher, Youwen Yang, Xufei Yang et al.
Journal of Hazardous Materials Advances
Indoor Air Quality and Microbial Exposure
article

Elevated airborne submicron particle counts linked to direct evaporative cooling in greenhouses

Seyit Uğuz, Mazhar Sher, Youwen Yang, Xufei Yang, Yajun Wu, Pradeep Adithya Kumar
article en

Abstract

• Direct evaporative cooling elevated airborne nanoparticle counts in greenhouses • The counts increased markedly from 0.15 m to 2.0 m downstream of cooling pads • Evaporation of saline droplets in greenhouses contributed to nanoparticle formation • Gas-particle conversion due to lower temperature and higher humidity is also likely Direct evaporative cooling (DEC) systems are widely used for climate control in agricultural, industrial, and residential environments. However, prolonged operation can lead to mineral scaling and biofilm fouling on cooling pads. To mitigate these issues, chemical additives are commonly introduced into the recirculating water. During system operation, fine saline droplets, similar to those produced by atomization, may contribute to airborne submicron particle (SP) formation, a phenomenon not yet investigated. This study compared airborne SP counts and size distributions in a greenhouse during active versus idle periods and accessed spatial distributions using three outdoor and nine indoor monitoring locations. Results revealed that indoor SP counts averaged 3,117±223 particles/cm 3 with the DEC system off and increased to 3,437±720 particles/cm 3 when on, as measured using a TSI NanoScan SMPS. Similar trends were observed using a CPC 3007 (off: 5,369±271 particles/cm 3 ; on: 6,416±1,128 particles/cm 3 ). SP counts increased significantly from 0.15 m downstream of the cooling pads to 2.1 m downstream, followed by a slight decrease at 4.0 m. This pattern contrasts with the gradual decline observed at these locations when the system was off. Particle size analysis revealed increased SP counts at 2.0 m downstream primarily occurred in the 11.5-27.5 nm, consistent with nanoparticles generated via atomization of diluted salt solutions. Overall, findings indicate that DEC operation can elevate airborne SP concentrations in built environments.

Journal of Hazardous Materials AdvancesVol. 21
South Dakota State University (US), Yozgat Bozok Üniversitesi (TR), Michigan State University (US)
Climate action
Openalex Percentile: Top 70%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.