Manufacturing-driven biocorrosion differences in the Mg-1Ca-0.5Zn-0.1Y-0.03Mn (at.%) alloy: An integrated in vitro and short-term in vivo evaluation

• RSRC alloy shows a refined, homogeneous microstructure with evenly distributed precipitates. • RSRC alloy shows lower corrosion rates and pH/osmolality shifts than IM and pure Mg. • Cytotoxicity tests confirmed RSRC alloy extracts were non-toxic to L929 fibroblasts. • RSRC alloy shows a slow in vivo degradation rate suitable for biodegradable implant use. While magnesium implants are already commercially available, exploring new manufacturing methods and alloy designs is essential to enhance their properties and clinical safety. This study assesses the in vitro and in vivo degradation of disc-shaped implants of the Mg-1Ca-0.5Zn-0.1Y-0.03Mn (at.%) alloy prepared by the rapidly solidified ribbon consolidation (RSRC) and hot extrusion of cast material (ingot metallurgy, IM). Electrochemical measurements and 28-day in vitro immersion tests were carried out under simulating physiological conditions. The cytotoxicity was evaluated by exposing L929 fibroblasts to RSRC Mg extracts. For the first time, the biocompatibility and degradation of the Mg-1Ca-0.5Zn-0.1Y-0.03Mn at.% alloy was assessed in a partial thickness calvaria defect model on male Wistar rats after 7 and 28 days of implantation. In vitro results showed that the RSRC alloy exhibited a more homogeneous microstructure and significantly lower corrosion rates compared to IM samples, with corrosion rates below 0.12 mm/year. The RSRC specimens exhibited lower pH and osmolality, and cytotoxicity assays confirmed that extracts from the RSRC alloy were non-toxic to L929 fibroblasts. In vivo , the RSRC alloys demonstrated slow degradation with corrosion rates remaining below 0.25 mm/year compared to pure Mg. Despite the presence of hydrogen gas cavities, new bone formation was observed suggesting that the RSRC alloy is a suitable material for the potential use as medical-grade absorbable Mg implants.

Authors

Institutions

Publication Details

Journal
Journal of Magnesium and Alloys
Published
2026-02-01
DOI
https://doi.org/10.1016/j.jma.2025.101973
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Manufacturing-driven biocorrosion differences in the Mg-1Ca-0.5Zn-0.1Y-0.03Mn (at.%) alloy: An integrated in vitro and short-term in vivo evaluation

Alessia Paradiso, Jakub Jaroszewicz, Diana C. Martinez, Katarzyna Pucia et al.
Journal of Magnesium and Alloys
Magnesium Alloys: Properties and Applications
article

Manufacturing-driven biocorrosion differences in the Mg-1Ca-0.5Zn-0.1Y-0.03Mn (at.%) alloy: An integrated in vitro and short-term in vivo evaluation

Alessia Paradiso, Jakub Jaroszewicz, Diana C. Martinez, Katarzyna Pucia, Anna Dobkowska, Yoshihito Kawamura, Wojciech Święszkowski, Artur Kamiński, Shin-ichi Inoue
article en

Abstract

• RSRC alloy shows a refined, homogeneous microstructure with evenly distributed precipitates. • RSRC alloy shows lower corrosion rates and pH/osmolality shifts than IM and pure Mg. • Cytotoxicity tests confirmed RSRC alloy extracts were non-toxic to L929 fibroblasts. • RSRC alloy shows a slow in vivo degradation rate suitable for biodegradable implant use. While magnesium implants are already commercially available, exploring new manufacturing methods and alloy designs is essential to enhance their properties and clinical safety. This study assesses the in vitro and in vivo degradation of disc-shaped implants of the Mg-1Ca-0.5Zn-0.1Y-0.03Mn (at.%) alloy prepared by the rapidly solidified ribbon consolidation (RSRC) and hot extrusion of cast material (ingot metallurgy, IM). Electrochemical measurements and 28-day in vitro immersion tests were carried out under simulating physiological conditions. The cytotoxicity was evaluated by exposing L929 fibroblasts to RSRC Mg extracts. For the first time, the biocompatibility and degradation of the Mg-1Ca-0.5Zn-0.1Y-0.03Mn at.% alloy was assessed in a partial thickness calvaria defect model on male Wistar rats after 7 and 28 days of implantation. In vitro results showed that the RSRC alloy exhibited a more homogeneous microstructure and significantly lower corrosion rates compared to IM samples, with corrosion rates below 0.12 mm/year. The RSRC specimens exhibited lower pH and osmolality, and cytotoxicity assays confirmed that extracts from the RSRC alloy were non-toxic to L929 fibroblasts. In vivo , the RSRC alloys demonstrated slow degradation with corrosion rates remaining below 0.25 mm/year compared to pure Mg. Despite the presence of hydrogen gas cavities, new bone formation was observed suggesting that the RSRC alloy is a suitable material for the potential use as medical-grade absorbable Mg implants.

Journal of Magnesium and Alloys
Warsaw University of Technology (PL), Medical University of Warsaw (PL), Kumamoto University (JP)
Openalex Percentile: Top 70%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.