TO RUST OR TO MRUST? RELIABILITY OF RADIOLOGICAL HEALING EVALUATION IN PATIENTS WITH DISTAL FEMUR FRACTURES DURING THE COURSE OF RECOVERY

Definition of radiographic distal femur fracture union is heterogeneous, largely non-specific, and not standardized. The purpose of this study was to evaluate the interobserver and intraobserver reliability of the standard radiographic union score for tibial (RUST) and modified RUST (mRUST) for distal femoral fractures over multiple consecutive time points. A prospective cohort of 196 patients who sustained a distal femur fracture (OTA 33-A, B, C) and underwent open reduction and internal fixation with a plate (NCB Zimmer) as part of an international, multicentre, randomized controlled trial (“Far Cortical Locking Versus Standard Constructs for Distal Femur Fractures (FCL)”) were retrospectively reviewed by four fellowship-trained orthopaedic trauma surgeons. Radiographs at standardized intervals (6 weeks, 3 months, 6 months, and 12 months) were blinded for treatment, timepoint and subject IDand were presented to readers in random order during 2 sessions 3 months apart Agreement was measured by intraclass correlation coefficient (ICC) The inter-observer ICC for the mRUST was slightly higher than the standard RUST in distal femur fractures, and had consistent good agreement at every time point. Reliability improved over time from ICC 0.61 at 6 weeks to 0.73 at 12 months. The Intra-observer reliability was good to excellent for both scores at all time points, and all cortices (ICC 0.71–0.82). The least reliable components of the RUST and mRUST scores were early in recovery the lateral and anterior components as they were often obscured by the plate (6 week ICC, mRust lateral (0.37, 0.45) anterior 0.45, 0.50). For assessment of healing in distal femur fractures, mRUST is more reliable throughout the first year of recovery, although neither functions optimally at time point critical for clinical decision making (6 weeks and 3 months). Lateral plates limit the reproducibility of specific cortical measurements, as such alterations in interpretation of scores may be warranted.

Authors

Publication Details

Journal
Orthopaedic Proceedings
Published
2026-02-03
DOI
https://doi.org/10.1302/1358-992x.2026.2.008
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TO RUST OR TO MRUST? RELIABILITY OF RADIOLOGICAL HEALING EVALUATION IN PATIENTS WITH DISTAL FEMUR FRACTURES DURING THE COURSE OF RECOVERY

D. Stockton, A. Flury, M-O. Dion, T. Kim et al.
Orthopaedic Proceedings
Bone fractures and treatments
article

TO RUST OR TO MRUST? RELIABILITY OF RADIOLOGICAL HEALING EVALUATION IN PATIENTS WITH DISTAL FEMUR FRACTURES DURING THE COURSE OF RECOVERY

D. Stockton, A. Flury, M-O. Dion, T. Kim, K. Lefaivre
article en

Abstract

Definition of radiographic distal femur fracture union is heterogeneous, largely non-specific, and not standardized. The purpose of this study was to evaluate the interobserver and intraobserver reliability of the standard radiographic union score for tibial (RUST) and modified RUST (mRUST) for distal femoral fractures over multiple consecutive time points. A prospective cohort of 196 patients who sustained a distal femur fracture (OTA 33-A, B, C) and underwent open reduction and internal fixation with a plate (NCB Zimmer) as part of an international, multicentre, randomized controlled trial (“Far Cortical Locking Versus Standard Constructs for Distal Femur Fractures (FCL)”) were retrospectively reviewed by four fellowship-trained orthopaedic trauma surgeons. Radiographs at standardized intervals (6 weeks, 3 months, 6 months, and 12 months) were blinded for treatment, timepoint and subject IDand were presented to readers in random order during 2 sessions 3 months apart Agreement was measured by intraclass correlation coefficient (ICC) The inter-observer ICC for the mRUST was slightly higher than the standard RUST in distal femur fractures, and had consistent good agreement at every time point. Reliability improved over time from ICC 0.61 at 6 weeks to 0.73 at 12 months. The Intra-observer reliability was good to excellent for both scores at all time points, and all cortices (ICC 0.71–0.82). The least reliable components of the RUST and mRUST scores were early in recovery the lateral and anterior components as they were often obscured by the plate (6 week ICC, mRust lateral (0.37, 0.45) anterior 0.45, 0.50). For assessment of healing in distal femur fractures, mRUST is more reliable throughout the first year of recovery, although neither functions optimally at time point critical for clinical decision making (6 weeks and 3 months). Lateral plates limit the reproducibility of specific cortical measurements, as such alterations in interpretation of scores may be warranted.

Orthopaedic ProceedingsVol. 108-B(SUPP_2)
Peace, Justice and strong institutions
Openalex Percentile: Top 67%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

TO RUST OR TO MRUST? RELIABILITY OF RADIOLOGICAL HEALING EVALUATION IN PATIENTS WITH DISTAL FEMUR FRACTURES DURING THE COURSE OF RECOVERY — D. Stockton, A. Flury, et al. · Orthopaedic Proceedings (2026) | TGRS Research Map | TGRS