Treatment of septic shock complicated by mediastinitis after HeartMate 3 BiVAD implantation using echo-guided device parameter optimization: a case report

Introduction : Septic shock complicated by poststernotomy mediastinitis in patients with mechanical circulatory support devices is a rare and life-threatening condition associated with high mortality. Management is particularly challenging because of the presence of prosthetic material and the risk of device contamination. Case presentation : We report a 63-year-old man with end-stage nonischemic cardiomyopathy who underwent HeartMate 3 biventricular assist device (BiVAD) implantation as bridge-to-transplant therapy. Four weeks after discharge, he was readmitted with septic shock, multiorgan failure, and mediastinitis. Treatment included broad-spectrum empirical antimicrobial therapy followed by targeted de-escalation, repeated surgical debridement with prolonged vacuum-assisted closure (VAC) therapy, continuous renal replacement therapy, and individualized echocardiography-guided optimization of BiVAD pump parameters to improve systemic perfusion. Device explantation was avoided. During rehabilitation, orthostatic collapse due to posture-dependent preload insufficiency was diagnosed using upright transesophageal echocardiography and resolved through targeted pump flow adjustment. Conclusion : This case demonstrates that severe septic shock and mediastinitis in BiVAD-supported patients can be successfully managed without device removal through multidisciplinary care, antimicrobial stewardship, VAC therapy, and dynamic echocardiography-guided device optimization.

Authors

Institutions

Publication Details

Journal
Pharmacia
Published
2026-02-03
DOI
https://doi.org/10.3897/pharmacia.73.e184514
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment of septic shock complicated by mediastinitis after HeartMate 3 BiVAD implantation using echo-guided device parameter optimization: a case report

Rumen Iliev, Yordan Makedonski, Philip Abedinov, Krasimir Petkov et al.
Pharmacia
Mechanical Circulatory Support Devices
article

Treatment of septic shock complicated by mediastinitis after HeartMate 3 BiVAD implantation using echo-guided device parameter optimization: a case report

Rumen Iliev, Yordan Makedonski, Philip Abedinov, Krasimir Petkov, Vera Tabakova, Stanislav Georgiev, Dimitar Petkov, Lyuboslava Pampulova
article en

Abstract

Introduction : Septic shock complicated by poststernotomy mediastinitis in patients with mechanical circulatory support devices is a rare and life-threatening condition associated with high mortality. Management is particularly challenging because of the presence of prosthetic material and the risk of device contamination. Case presentation : We report a 63-year-old man with end-stage nonischemic cardiomyopathy who underwent HeartMate 3 biventricular assist device (BiVAD) implantation as bridge-to-transplant therapy. Four weeks after discharge, he was readmitted with septic shock, multiorgan failure, and mediastinitis. Treatment included broad-spectrum empirical antimicrobial therapy followed by targeted de-escalation, repeated surgical debridement with prolonged vacuum-assisted closure (VAC) therapy, continuous renal replacement therapy, and individualized echocardiography-guided optimization of BiVAD pump parameters to improve systemic perfusion. Device explantation was avoided. During rehabilitation, orthostatic collapse due to posture-dependent preload insufficiency was diagnosed using upright transesophageal echocardiography and resolved through targeted pump flow adjustment. Conclusion : This case demonstrates that severe septic shock and mediastinitis in BiVAD-supported patients can be successfully managed without device removal through multidisciplinary care, antimicrobial stewardship, VAC therapy, and dynamic echocardiography-guided device optimization.

PharmaciaVol. 73
University Hospital St. Marina (BG)
Good health and well-being
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.