A Bayesian framework for the detection of physiological pulmonary ventilation changes

<i>Objective.</i>The assessment of regional ventilation changes from functional ventilation data can provide essential information regarding treatment response in lung cancer radiotherapy (RT). However, this task can be challenging since ventilation maps contain noisy measurements and artifacts.<i>Approach.</i>We introduce a Bayesian framework that identifies physiological changes from a set of longitudinal ventilation scans. The proposed framework was calibrated and validated using synthetic datasets. Its ability to correctly classify regions of true change was evaluated using the sensitivity, precision and Dice Similarity coefficient. We also applied our model to a dataset comprising 11 lung cancer patients for whom multiple 4DCT scans were obtained during the course of RT treatment. CT-derived ventilation maps were generated and used as input to the proposed framework. In order to create a control dataset where no functional changes were expected, we also shuffled the time points for the 11 patients in every possible way that discarded as much temporal information as possible resulting in 128 functional map sequences.<i>Main results.</i>In the synthetic validation dataset, the average (standard deviation) of the sensitivity, precision and Dice Similarity coefficient was 0.72 (0.26), 0.95(0.05) and 0.78 (0.22) respectively. In the patient dataset, 3/11 patients were identified with significant functional decline and 4/11 with functional increase that was associated with tumor regression. Finally, in the control dataset the frequency of occurrence of significant changes was 1.6% (4/256) compared to 32% (7/22) for the original patient dataset.<i>Significance.</i>We have developed a framework for analyzing functional ventilation changes from longitudinal data. The results of the lung cancer patient dataset indicate that significant functional increase and decline can occur during the course of RT treatment. More generally, the developed framework can be used to assess ventilation changes with the potential of guiding adaptive treatment strategies.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-02-03
DOI
https://doi.org/10.1088/1361-6560/ae4161
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Bayesian framework for the detection of physiological pulmonary ventilation changes

Cornel Zachiu, Bas W. Raaymakers, Mario Ries, Paris Tzitzimpasis
Physics in Medicine and Biology
Radiomics and Machine Learning in Medical Imaging
article

A Bayesian framework for the detection of physiological pulmonary ventilation changes

Cornel Zachiu, Bas W. Raaymakers, Mario Ries, Paris Tzitzimpasis
article en

Abstract

<i>Objective.</i>The assessment of regional ventilation changes from functional ventilation data can provide essential information regarding treatment response in lung cancer radiotherapy (RT). However, this task can be challenging since ventilation maps contain noisy measurements and artifacts.<i>Approach.</i>We introduce a Bayesian framework that identifies physiological changes from a set of longitudinal ventilation scans. The proposed framework was calibrated and validated using synthetic datasets. Its ability to correctly classify regions of true change was evaluated using the sensitivity, precision and Dice Similarity coefficient. We also applied our model to a dataset comprising 11 lung cancer patients for whom multiple 4DCT scans were obtained during the course of RT treatment. CT-derived ventilation maps were generated and used as input to the proposed framework. In order to create a control dataset where no functional changes were expected, we also shuffled the time points for the 11 patients in every possible way that discarded as much temporal information as possible resulting in 128 functional map sequences.<i>Main results.</i>In the synthetic validation dataset, the average (standard deviation) of the sensitivity, precision and Dice Similarity coefficient was 0.72 (0.26), 0.95(0.05) and 0.78 (0.22) respectively. In the patient dataset, 3/11 patients were identified with significant functional decline and 4/11 with functional increase that was associated with tumor regression. Finally, in the control dataset the frequency of occurrence of significant changes was 1.6% (4/256) compared to 32% (7/22) for the original patient dataset.<i>Significance.</i>We have developed a framework for analyzing functional ventilation changes from longitudinal data. The results of the lung cancer patient dataset indicate that significant functional increase and decline can occur during the course of RT treatment. More generally, the developed framework can be used to assess ventilation changes with the potential of guiding adaptive treatment strategies.

Physics in Medicine and BiologyVol. 71(5)
Utrecht University (NL), University Medical Center Utrecht (NL)
Good health and well-being
Openalex Percentile: Top 69%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.